Below: selecting the relay in advanced training mode
SW1
OFF
ON
OFF
ON
PLEASE NOTE
In advanced training mode, care must be taken when mixing four-key remote controls (keys 1 to 4) and key
numbers above 4 (keys 5 to 24):
An ADD operation for a chosen relay with a key ≥ 5 will be seen as a global addition (for example, key 5 will be
associated with relay 1, key 6 will be associated with relay 2, key 7 will be associated with relay 3, key 8 will be
associated with relay 4).
A REMOVE operation for a chosen relay will lead to global removal if recording has been carried out for a key ≥
5 (for example, if key 5 is associated with relay 1, key 6 with relay 2, key 7 with relay 3, and key 8 with relay 4,
ALL the associations will be removed).
An ERASE operation for a chosen relay will lead to global erasure if recording has been carried out for a key ≥ 5
(for example, if key 5 is associated with relay 1, key 6 with relay 2, key 7 with relay 3, and key 8 with relay 4, ALL
the associations will be erased).
2.8.2 Global erase procedure
Global ERASE operation
1/ Select «Erase» mode with SW4 ON.
2/ Select SW3 ON and SW5 OFF.
3/ Press any key on any valid remote control.
4/ Exit «Erase» mode with SW4 OFF.
Result of the operation:
No relay can now be activated by any remote-control. The LED flashes twice.
2.9.
Bistable / monostable operation
In operating mode (when training has been finished), users can choose whether the relays will operate in monos-
table or bistable mode. As described below, SW3-SW4-SW5 must be set to OFF.
SW1
OFF
ON
SW2
OFF
ON
Gamme ARF18 UG V1.6
SW2
Relay 1
OFF
Chosen
OFF
ON
ON
Relays 1 and 2
Monostable
Bistable
Relays 3 and 4
Monostable
Bistable
Relay 2
Relay 3
Chosen
Chosen
SW3-SW4-SW5
OFF-OFF-OFF
OFF-OFF-OFF
SW3-SW4-SW5
OFF-OFF-OFF
OFF-OFF-OFF
Relay 4
Chosen
49