5.5.
«OEM» product technical specification
Frequency:
Modulation:
Sensitivity:
Power supply (VDC):
Rx consumption (permanent listening)
Size (mm):
Operating temperature:
6.
ARF7293/7294 «OEM» receiver training procedures
The training procedure for the ARF 18 receiver permits the configuration of the system in the following manner:
•
All the remote control's keys can control any output on the receiver.
•
One or more remote controls can control the same outputs.
•
Any remote control key can control from 1 to 4 outputs on the receiver.
•
The training process can be initiated either by input switches, or by AT commands via the serial link.
This document also describes the functionality of the receiver after configuration:
•
Monostable or bistable functionality of the digital outputs via input switches.
•
Transmission of each remote control serial number via the serial link.
Please note: for an 8/24 key remote control, certain training combinations are not available; cf section «8/24 key
training characteristics».
6.1.
Hardware interface
This section describes the inputs and outputs of the module used to control training mode. The pins may change
according to the model of the receiver module. Please check the receiver's user guide,
Pin name
Add/Remove
Erase
Gamme ARF18 UG V1.6
Radio characteristics
Electrical characteristics
Mechanical characteristics
Direction
Description
Input
Logic '1' assigned: The «Add/Remove» function is disabled.
Logic '0' assigned: The «Add/Remove» function is enabled.
Input
Logic '1' assigned: The «Erase» function is disabled.
Logic '0' assigned: The «Erase» function is enabled.
433.92 MHz
ASK
-104 dBm
3.3VDC +/- 10%
15mA
43.6 x 23.2 mm
-20 to +70 °C
60