FAQ
The answers are listed below in summary form, for further details see the other pages of this document.
1) What do I need to prepare in order to install the boiler-fi replace?
Smoke outlet that is at least 100 mm in diameter.
An air inlet in the room that is at least 80 cm².
1" outlet and inlet fi tting.
¾" G drains connection for overpressure valve.
¾" G load fi tting.
A certifi ed electrical connection with a thermal magnetothermic switch 230V +/- 10% 50 Hz.
(assess the division of primary and secondary circuits).
2) Can the boiler work without water?
NO. Using the boiler without water will damage it.
3) Can I connect the inlet and outlet of the boiler-fi replace directly to a radiator?
NO. Practically all of the heat produced is transferred to the water.
It is advisable in any case to use a radiator in the same room.
4) Can I connect the inlet and outlet of the boiler directly to a radiator?
NO, just like other boilers, it must be connected to a collector from which the water is then distributed to the radiators.
5) Do boiler also supply hot sanitary water?
It is possible to produce hot sanitary water evaluating the power of the boiler and the water plant.
6) Can I discharge the smoke from the boiler along the wall?
NO, a discharge which is conform with standards (UNI 10683) must reach the ridge of the roof, and in any case proper functio-
ning requires a vertical stroke of at least 1.5 meters; avoiding that in case of power outage or wind, a slight amount of smoke
forms in the installation environment.
7) Do I need an air inlet in the room where it is installed?
Yes, to replenish the air used by the boiler for combustion.
The smoke extractor draws the air from the room into the combustion chamber.
8) What settings are required on the boiler display?
The desired water temperature; the boiler will then adjust the power accordingly to obtain or maintain this.
For small systems, a mode can be set that ignites and shuts down the boiler accordingly, as the water temperature is reached.
(contact DEALER for initial start up)
9) Do I need to vacuum the pellet hopper?
Yes, at least once a month when the boiler is not used for some time.
10) Can I burn other fuel apart from pellets?
NO. The boiler has been designed to burn wood pellets that are 6 mm in diameter. Any other material can damage it.