3.2.2 Alarm codes
E99
General alarm
E01, E02
Temperature alarm
E10
Power module alarm
E19
System configuration alarm
E13
Communication alarm
E20
Memory fault alarm
E21
Data loss alarm
E23
Memory fault alarm (RC)
E24
Data loss alarm (RC)
E40
System power supply alarm
3.3 Rear panel
1
Power supply cable
Connects the system to the mains.
2
Signal cable (CAN-BUS) input (RC)
(Quasar 270 RC - Quasar 350 RC)
3
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.
3.4 Sockets panel
1
Negative power socket
For connection of earth cable in electrode welding or of
torch in TIG.
2
Positive power socket
For connection of electrode torch in MMA or earth
cable in TIG.
4 ACCESSORIES
4.1 General
Operation of the remote control is activated when connected
to the Selco power sources. This connection can be made also
with the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.
4.2 RC 100 remote control
The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
"Consult the instruction manual".
4.3 RC 200 remote control
The RC 200 is a remote control unit designed to manage the
display and the adjustment of all available parameters of the
power source to which it is connected.
"Consult the instruction manual".
4.4 RC 180 remote control
This remote control unit makes it possible to change the output
current without interrupting the welding process.
"Consult the instruction manual".
25