TROUBLESHOOTING
PROBLEM
Water will not flow
from shower head
Burner will
not light
Water is not
hot enough
E0
E1
E2
E3
E4
E6
E7
Check that pump debris filter is not clogged
Check that appliance is switched on
Check sufficient water is available
Check that the pump is connected to the appliance
Make sure the battery is charged
Check for kinks in shower hose
Check that pump fuse is not blown
Check that the shower head ON/OFF switch is in the open position
Check that there is gas in cylinder
Check that the water is flowing from shower head
Check that water is not over temperature
Check that battery does not require re-charging
Check the Flow Switch on shower head make sure it is fully open
Check gas control
Check source water temperature (water temps below 50°F might require recirculation)
Cycle the water through the system back in to the source reservoir then through the appliance again
Reduce flow using the flow valve
LED DIAGNOSTIC
Inlet Temperature Sensor Failure
Flame Sensor Error
Water Flow Error
Unsuccessful Ignition/Flame Out
Outlet Temperature Sensor Fault
Back Up Water Temperature High Limit Fault
(131°F, 55° C)
Primary Water Temperature High Limit Switch Fault
(122°F, 50° C)
DO NOT ATTEMPT TO
MODIFY THE APPLIANCE
Basecamp, Inc. | Portable Shower
SOLUTION
TROUBLE SHOOTING
This guide should be followed in case of failure of the
appliance to operate correctly. If symptoms persist
contact Technical Service 1-800-251-0001
8
Operating Instructions and OwnerÊs Manual