7.5 REPLACEMENT TRACER FLAT KEY
Follow the steps below to change the tracer:
1)
Switch the machine off using the emergency stop and disconnect the cable from the power supply.
2)
Raise the front plastic guard.
3)
Unscrew the two screws (T10).( Fig.25)
4)
Replace the tracer and tighten again the screws.
(NOTE: In the case of installing a new tracer, the tracer will have to be adjusted) (see section 3.2.1)
70
T8
FIG. 24
FIG. 25
T9
T10