3.3 Nameplate information

3.3 Nameplate information
Pump nameplate
Nameplate field Explanation
Type*
S/N*
Q
P
H
n
P
all w C
t
max op
Item No
Imp Ø
MATL
*All details of design and materials are defined with this information. You must specify these details
when you order spare parts.
ATEX nameplate
The conformity with the EC directive 94/9/EG "Appliances and Protection Systems for designated
use in areas endangered to explosion" is declared by the issue of the EC Declaration of Conformity
and the attachment of the ATEX label on the bearing bracket of the pump. The ATEX label is also
attached to the pump nameplate.
Nameplate field Explanation
CE
Ex
II
2G
c
T1-T.
16
Type of pump
Serial number
Rated pump flow, in cubic meters per hour
Rated pump power, in kilowatts
Rated pump head, in meters
Rated pump speed, in min
Maximum permitted casing-operation-pressure (Highest discharge pressure at the rated oper-
ating temperature to which the pump casing can be used)
Maximum permitted operating temperature of pumped liquid
Customer-related order number
Outer diameter of the impeller
Material of construction
Marking of compliance with the EC directive 94/9/EG
Specific marking for explosion protection
Appliance group
Category (2) and explosive atmosphere due to gases, vapors, or mist (G)
ignition protection in use: constructual safety (c)
Classification of the theoretically available range of the temperature classes
Model ICO i-FRAME, ICOH i-FRAME Manual de instalación, funcionamiento y mantenimiento