Display
Function
P 1
Output 1 Polarity
Allows setting of the output polarity:
Y
output NC
no
output NO
NOTE: if the output setting is
keep the value set to
o2
Output 2
Output 2 signal type, see "Output 1"
P2
Output 2 Polarity
Output 2 polarity, see parameter regarding
"Output 1 Polarity"
o3
Output 3
Output 3 signal type, see "Output 1"
P3
Output 3 Polarity
Output 3 polarity, see parameter regarding
"Output 1 Polarity"
o4
Output 4
Output 4 signal type, see "Output 1"
P4
Output 4 Polarity
Output 4 polarity, see parameter regarding
"Output 1 Polarity"
o5
Integrated flashing lamp operating mode
Lets you choose between two operating modes
for the integrated flashing lamp (if present)
connected to output J15.
0 1
"Traffic light" mode (steady green
when paused/open, flashing red when
moving, steady red when closed)
02
"Flashing lamp" mode (flashing red
when bar is moving, off in all other
cases)
AS
Service request (linked to the following
two functions):
If activated, at the end of the countdown
(which can be set with the two following "Cycle
Programming" functions) it activates the LAMP
output for 4 sec every 30 sec (service request).
It can be useful for setting programmed
maintenance work.
Y
no
Active
Disabled
nc
Cycle programming in thousands:
Is used to set a countdown of the system
operation cycles; the value can be set from
0 to 99 (thousands of cycles). The value
displayed is updated with the succession of
the cycles, interacting with the value of
(99 decrements of
nC
decrement of
).
The function can be used, together with
to verify the use of the system and for use of
"Service Request".
Default
no
00
(Failsafe),
no
03
no
19
no
0 1
no
0 1
no
00
n C
nc
correspond to 1
nC
,
Display
Function
nC
Cycle programming in hundreds of
thousands:
Is used to set a countdown of the system
operation cycles; the value can be set from 0
to 99 (hundreds of thousands of cycles). The
value displayed is updated with the succession
of the cycles, interacting with the value of
nc
. (1 decrement of
nc
decrements of
The function can be used, together with
to verify the use of the system and for use of
"Service Request".
St
AUTOMATED SYSTEM STATUS:
This allows you to choose whether to quit the programme
and save the data.
Y
= quit and save the data
no
= quit without saving the data
On quitting the programme, press the F key to display
again the status of the automated system.
You can go to St at any time by simultaneously
pressing F and -
6.1 Configuring the loop detector
The E680 board features an integrated metal mass detector for the
induction detection of vehicles.
6.1.1 Specifications:
•
Galvanic separation between the detector electronics and the
loop electronics
•
Automatic alignment of the system immediately following
activation
•
Continuous resetting of the frequency drifts
•
Sensitivity independent of loop inductivity
•
Adjustment of the loop work frequency with automatic selection
•
Occupied loop message with LED display
•
Loop status addressable on outputs OUT 1, OUT 2, OUT 3 and
OUT 4
6.1.2 Connection:
Connect the detection loops according to the layout on page 7,
Fig. 2
- Terminals 24 - 25 for LOOP 1 = loop with gate opening function;
- Terminals 26 - 27 for LOOP 2 = loop with closing and/or safety
when closing function.
For more information on the effect of the loop signals on the automated
system, refer to the logics tables in paragraph 10 "OPERATING
LOGICS TABLE".
To enable the functionality of the connected loops, enter Basic
configuration mode and set parameters
with the number and type of connected loops. If only one loop is
installed, enable only the corresponding programming step.
The loop detector operating status is indicated by the DL3 and DL4
status LEDs.
13
Default
nC
corresponds to 99
).
n c
,
L1
L2
Y
and
on
consistently
0 1