Part 3: Reserved for Author. and Qualified Techn.
DISPLAYED ALARMS and WARNINGS: SELF-DIAGNOSTICS
It an ALARM or WARNING condition occurs, the relative code will be displayed.
The START key turns RED until normal conditions are restored.
ATTENTION
If more than one alarm is triggered simultaneously,
the display will show the relative codes based on this
order of priority:
1. H1-H2-H3
2. A1-A2-A3-A4-A5-A6-A9
3. F1-F2-F3
The alarm and warning codes of the active functions
displayed during machine operation are:
A1
CYCLE NOT COMPLETED
This alarm is displayed when the wash cycle was
interrupted by switching the machine off with
the START key.
The alarm is reset when the next wash cycle
starts
A2
ANOMALOUS OVERHEATING (BOILER)
This alarm is displayed when the temperature in the
boiler exceeds 105°C or when at least one
of the temperature probes (tank/boiler) is
short-circuited. The alarm is reset when the
temperature drops below 102°C or when the
probe is replaced
A 3
TEMPERATURE PROBE DISCONNECTED
This alarm is displayed when one of the
temperature probes (boiler and/or tank) is
disconnected or interrupted.
The alarm is reset when the probe is reconnected
properly
A 4
FILLING TIMEOUT (RCD versions)
This alarm is displayed when the tank does not fill
within 30 minutes or the boiler does
not fill within 6 minutes.
The alarm can be reset by pressing the
START key
A1
A2
A3
TIME OUT FILLING
A4
START
START
A 5
BOILER HEATING TIMEOUT
This alarm is displayed when the boiler is not heated
within 30 minutes. The alarm can be reset by
pressing the START key
T°S2
A6
WATER DRAINING TIMEOUT (partial dumper)
This alarm is displayed if the drain cycle does not
finish within 4 minutes.
The alarm can be reset by pressing the START key
A9
REGENERATION
This alarm is displayed when it is reached
of the set cycles
A9
A10
FULL TANK
This alarm is displayed if once started
the regeneration phase the tank was not empty
A10
H 1
INSUFFICIENT RINSE WATER TEMPERATURE
This alarm is displayed if, during the wash cycle,
the rinse phase is carried out with the boiler
at least 15°C lower than the set temperature.
The washing cycle is prolonged until the
maximum rinsing temperature is reached
(max 8 minutes).
H2
WATER MISSING
This alarm is displayed when water is detected to
be missing.
The alarm can be reset by pressing the START key.
ENGLISH
BOILER
A5
A6
H1
H2
27