2. When you want to know position of the indoor unit using the address
• To confirm the unit numbers in a group control;
[Procedure] (Operation while the air conditioner stops)
The indoor unit numbers in a group control are successively displayed, and the corresponding indoor fan is turned on.
1
VENT
TEST
Push
+
buttons simultaneously for 4
seconds or more.
• Unit No
is displayed.
• The fans of all the indoor units in a group control are
turned on.
2
UNIT
Every pushing
bers in the group control are successively
displayed.
• The firstly displayed unit number on number indicates
the address of the header unit.
• Only fan of the selected indoor unit is turned on.
3
TEST
Push
button to finish the procedure.
All the indoor units in group control stop.
• To confirm all the unit numbers from an arbitrary wired remote controller;
[Procedure] (Operation while the air conditioner stops)
The indoor unit number and position in the same refrigerant line can be confirmed. An header unit is selected, the
indoor unit numbers in the same refrigerant system are successively displayed, and then its indoor unit fan is
turned on.
1
Push the timer time
Firstly, the line 1, item code
2
UNIT
Using
and
SWING/FIX
address.
3
SET
Using
button, determine the selected line
address.
• The indoor address, which is connected to the
refrigerant system of the selected refrigerant system is
displayed and the fan is turned on.
4
UNIT
Every pushing
numbers in the same refrigerant system are suc-
cessively displayed.
• Only fan of the selected indoor unit operates.
[To select another line address]
5
CL
Push
button to return to procedure
• The indoor address of another line can be successively
confirmed.
6
TEST
Push
button to finish the procedure.
button, the indoor unit num-
TEST
+
buttons simultaneously for 4 seconds or more.
AC
(Address Change) is displayed. (Select outdoor unit.)
buttons, select the line
button, the indoor unit
2
.
3
FILTER
End
RESET TEST
1
Operation procedure
1
1
FILTER
RESET TEST
6
3
Operation procedure
1
4
32
CODE No.
SET
DATA
SETTING
UNIT No.
R.C.
No.
TEMP.
ON / OFF
TIMER SET
FAN
MODE
TIME
SWING/FIX
VENT
SET CL
UNIT
®
®
2
3
End
CODE No.
SET
DATA
SETTING
UNIT No.
R.C.
No.
TEMP.
ON / OFF
TIMER SET
FAN
MODE
TIME
SWING/FIX
VENT
SET CL
UNIT
®
®
®
2
3
®
®
5
6
End
1
2
2
4
5

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido