12 = second compressor step output;
13 = second compressor step output with rotation.
Warning: mode H1/H5=0 is useful for signalling the alarm status even when power is cut off.
Note: in the models fi tted with only one auxiliary output, to associate the button
the relay assigned to aux 1 to the auxiliary output 2. The operation can be performed using the programming kit PSOPZPRG00 and the programming
key PSOPZKEY00/A0.
Date and day of defrost event (parameters td1 to td8)
0= no event; 1 to 7= Monday to Sunday; 8= from Monday to Friday; 9= from Monday to Saturday; 10= Saturday and Sunday; 11= every day.
4. SUMMARY OF OPERATING PARAMETERS
UOM = Unit of measure; Def. = Default value
Symbol
Code
Parameter
Pw
Password
/2
Measurement stability
/3
Probe display rate
/4
Virtual probe
/5
Select °C or °F
/6
Decimal point
/tI
Display on internal terminal
/tE
Display on external terminal
/P
Select type of probe
/A2
Confi guration of probe 2
/A3-4-5
Confi guration of probes 3-4-5
/c1-2-3-4-5
Calibration of probes 1-2-3-4-5
St
Set point temperature
rd
Control delta
rn
Dead zone
rr
Reverse control delta with dead zone
r1
Minimum set point allowed
r2
Maximum set point allowed
r3
Operating mode
r4
Automatic night-time set point variation
r5
Enable temperature monitoring
rt
Temperature monitoring interval
rH
Maximum temperature read
rL
Minimum temperature read
c0
Compressor, fan and AUX start delay at power on, in
control with dead zone
c1
Minimum time between successive starts
c2
Minimum compressor OFF time
c3
Minimum compressor ON time
c4
Duty setting
cc
Continuous cycle duration
c6
Alarm bypass after continuous cycle
c7
Maximum Pump-Down time
c8
Compressor start delay after opening PD valve
c9
Enable autostart function with operation in PD
c10
Select Pump-Down by time or pressure
c11
Delayed compressor delay
d0
Type of defrost
dI
Interval between defrosts
dt1
End defrost temperature, evaporator
dt2
End defrost temperature, aux evaporator
dP1
Maximum defrost duration, evaporator
dP2
Maximum defrost duration, aux evaporator
d3
Defrost start delay
d4
Enable defrost at start-up
d5
Defrost delay at start-up
d6
Display on hold during defrost
dd
Dripping time after defrost
d8
Alarm bypass after defrost
d8d
Alarm bypass after door open
d9
Defrost priority over compressor protectors
d/1
Display defrost probe
d/2
Display defrost probe
dC
Time base for defrost
d10
Compressor running time
to this output, set H1 = 10 and H5 = 3. It is necessary to associate
AD
U.M.
AD
AD
AD
AD
AD
AD
AD
AD
AD
D
A
AD
AD
°C/°F
AD
°C/°F
AD
°C/°F
AD
°C/°F
AD
°C/°F
AD
°C/°F
AD
°C/°F
AD
AD
°C/°F
AD
AD
hours
AD
°C/°F
AD
°C/°F
AD
AD
AD
AD
AD
AD
hours
AD
hours
AD
AD
AD
AD
AD
AD
AD
hours
AD
°C/°F
AD
°C/°F
AD
AD
AD
AD
AD
AD
AD
AD
hours
AD
hours/min
AD
AD
°C/°F
AD
°C/°F
AD
AD
hours
7
Type
Def.
Max.
-
C
22
200
-
C
4
15
-
C
0
15
-
C
0
100
fl ag
C
0
1
fl ag
C
0
1
-
C
1
7
-
C
0
6
-
C
0
2
-
C
2
4
-
C
0
4
-
C
0
4
C
0.0
20
F
0.0
r2
F
2.0
20
C
4.0
60
C
2.0
20
C
-50
r2
C
60
200
fl ag
C
0
2
C
3.0
20
fl ag
C
0
1
F
-
999
F
-
-
F
-
-
min
C
0
15
min
C
0
15
min
C
0
15
min
C
0
15
min
C
0
100
C
0
15
C
2
15
s
C
0
900
s
C
5
60
fl ag
C
0
1
fl ag
C
0
1
s
C
4
250
fl ag
C
0
4
F
8
250
F
4.0
200
F
4.0
200
min
F
30
250
min
F
30
250
min
C
0
250
fl ag
C
0
1
min
C
0
250
-
C
1
2
min
F
2
15
F
1
15
C
0
250
fl ag
C
0
1
F
-
-
F
-
-
fl ag
C
0
1
C
0
250
+050004105 rel. 1.1 del 17.11.05
Min.
0
1
0
0
0
0
1
0
0
0
0
-20
r1
0.1
0.0
0.1
-50
r1
0
-20
0
0
-
-
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-50
-50
1
1
0
0
0
0
0
0
0
0
-
-
0
0

Publicidad

Tabla de contenido
loading

Tabla de contenido