Hold coupling
nut and regulator
as shown for proper connection
to LP tank valve.
Leak Testing Valves, Hose and Recjulator
1. Turn all grill control knobs to OFF:.
2. Be sure regulator
is tightly
connected
to LP tank.
.
Completely
open LP tank valve by turning
OPD hand wheel
counterclockwise.
If you hear a rushing sound, turn gas off
immediately.
There is a major
leak at the connection.
Correct
before proceeding
by calling
for replacement
parts at
1-800-4-MY-HOME_
4. Brush soapy solution onto areas where bubbles
are shown in
picture
below:
6. Turn the coupling
nut clockwise
and tighten
to a full stop. The
regulator
will seal on the back-check
feature
in the LP tank
valve, resulting
in some resistance. An additional
one-half
to
three=quarters
turn is required
to complete
the
connection.
Tighten
by hand only - do not use tools.
NOTE:
If you cannot complete
the connection,
disconnect
regulator
and repeat steps 5 and 6. If you are still unable to complete
the
connection, d o not
use this regulator!
®
Call 1-800-4-MY=HOME
for identical
replacement
parts.
" Do not insert any tool or foreign
objects
into the valve
outlet or safety relief valve. You may damage
the
valve and cause a leak. Leaking
propane
may result in
explosion,
fire, severe personal
injury, or death.
" If a leak is detected
at any time, STOP and call the fire
department.
" If you cannot
stop a gas leak, immediately
close LP tank
valve and call LP gas supplier or your fire department!
Never remove threaded
orifice at end of valve.
5. if "growing"
bubbles
appear,
there is a leak. Close LP tank
valve immediately
and retighten
connections,
if leaks cannot
be stopped
do not try to repair. Call for replacement
parts at 1-800-4-MY-HOME.
®
6. Always
close LP tank valve after
performing
leak test by
turning
hand wheel clockwise.
• Never attempt to attach this grill to the self-contained
LP gas
system of a camper
trailer or motor
home.
• Do not use grill until leak-tested.