Troubleshooting (continued)
Burner(s) will not
light
using ignitor.
(See Electronic
ignition
Troubleshooting
also)
Burner(s) will not
match
light.
Sudden drop in gas
flow or low flame.
Flames blow
out.
Flare-up.
ELECTRONIC
iGNiTiON:
" No spark, no ignition
noise.
" No spark, some ignition
noise.
" Sparks, but not at electrode
or at full
strength.
" See "GAS
iSSUES:" on previous
page.
" Match
will not reach.
" improper
method
of match-lighting.
" Out of gas.
" Excess flow
valve tripped.
" Vapor
lock at coupling
nut/LP
cylinder
con nection.
" High or gusting
winds.
" Low on LP gas.
" Excess flow
valve tripped.
" Grease
buildup.
" Excessive fat in meat.
" Excessive cooking
temperature.
" Grease
trapped
by food
buildup
around
burner
system.
" Burner and/or
burner tubes are
blocked.
" Some dealers
have older
fill nozzles
with worn threads.
" Grease
buildup
or food
particles
in
end(s) of carryover
tube(s).
" See Section
I of Electronic
ignition
System.
" See Section
II of Electronic
ignition
System.
" See Section
III of Electronic
Ignition
System.
" Use long=stem
match
(fireplace
match).
" See "Match=Lighting"
section
of Use and Care.
" Check for gas in LP cylinder.
" Turn off knobs, wait 30 seconds and light grill, if flames
are still
low, turn off knobs and LP cylinder
valve.
Disconnect
regulator.
Reconnect
regulator
and leak=test. Turn on LP cylinder
valve,
wait 30 seconds and then light grill.
" Turn off knobs and LP cylinder
valve.
Disconnect
coupling
nut
from cylinder.
Reconnect
and retry.
" Turn front of grill to face wind
or increase
flame
height.
" Refill LP cylinder.
" Refer to "Sudden
drop
in gas flow"
above.
" Clean
burners and inside of grill/firebox.
" Trim fat from meat
before
grilling.
" Adjust
(lower)
temperature
accordingly.
Persistent
grease fire.
" Turn knobs to OFF. Turn gas off at LP cylinder.
Leave lid in
position
and let fire burn out. After grill cools, remove
and clean
all parts.
Flashback...
" Turn knobs to OFF. Clean
burner
and!or
burner
tubes. See
(fire in burner tube(s)),
burner
cleaning
section
of Use and Care.
Unable
to fill LP
" The worn nozzles don't
have enough
"bite"
to engage
the valve.
cylinder.
Try a second
LP dealer.
One burner
does not
" Clean carry-over
tube(s) with wire brush.
light from other
burner(s).
464323313