4 ASSIGNMENT OF INTERNAL FAULT 999

0-1999 internal faults generated from within System apI
D1
D2
10
return value of m_PwrOn_uiInitAPI()
20
0
21
0
22
Erroneous State
40
0
92
Directive
200
0
201
0
202
0
203
0
204
0
210
sEECtrl.sChk.uiReadStartAddr
211
sEECtrl.sChk.uiReadStartAddr
212
sEECtrl.eSeq_State
215
uiEEFaultAddr
216
uiEEFaultAddr
217
uiEEFaultAddr
220
0
222
uiEEStartAddr
240
uiEEStartAddr
241
uiEEStartAddr
242
uiEEStartAddr
243
uiEEStartAddr
244
ulReqFIFOSpace
250
(ulong32)pucDst
300
0
301
0
350
0
360
0
361
0
380
uiBPP_HPPunktNr
381
0
382
0
383
uiBCP_AnzParam[0]
384
uiBCP_AnzParam[1]
385
sRx.Buffer.ui[ucRxOk-1][uiSTART-
BEF+47]
386
uiParaIdx
410
sIO.sIn.ulInputsN
411
input status received from UP
412
0
420
uil
430
ucPin2Test
431
ucPin2Test
440
0
m_PwrOn_uiInitAPI() failed
CRC32 check of ROM failed
Cyclic CRC32 check of ROM during runtime failed
State machine for CRC32 check during runtime ran into an invalid state
m_PwrOn_bLoadEEPROM() failed
ATTENTION, wrong number in the wrong module, signaled by hchactab if control
tables are not correct
Last destination element is no member of sER.sP
Last destination element is no member of sER.sM
Last destination element is no member of sER.sC
Last destination element is no member of sER.sH
Destination is no member of sER.sX
Refresh cycle timeout expired
Uncorrectable error in EEPROM block
Invalid state
Uncorrectable error in Parameter Set
Uncorrectable error in Miscell-Data
Uncorrectable error in Curve Set
pucDst == NULL
Invalid EEPROM address
Write beyond end of safety area!
Start address in safety area is no multiple of 3
Write beyond end of non-safety area!
Start address is in reserved area!
Not enough FIFO space
Readback error while refreshing - possibly defective RAM cell
Timout sICom.uiRxLiveTimer expired
Timout sICom.uiRxLiveTimer expired
Timeout sICom.uixLiveTimer expired
Timeout while waiting for the exit from DUAL_BEF_CHECk_PARAM
FIFO ful !
Error while calling uiPutPunkt()
Seal control command in the presence of BM_FAT_kALTCHECk
Timeout in the cyclical parameter comparison
DUAL_BEF_CHANGE_PARAM1: Invalid value in the reception buffer
DUAL_BEF_CHANGE_PARAM2: Invalid value in the reception buffer
Cyclic parameter verification: different parameters between HP and UP!
PowerOn parameter verification: different parameters between HP and UP!
Detected positive half-wave on terminal input!
Different input status between controllers
The readback input of the fuel selection relais contacts in the dual fuel is invalid. DFM
probably defect.
Input status of digital input on HP and UP is inconsistent (>20ms)
Pin short circuit test detected an error!Currently tested pin not configurated as output
or is stuck at 1
Pin short circuit test detected an error!Short-circuit between pins, pull-up of input stage
defective or pin is externally stuck at 0
sIO.sIn.uiTestSignalTimeout expired