ONLY THERMO FIREPLACES THAT HAVE A THERMAL RELIEF VALVE
WHICH ACTUATES THE COIL CAN BE INSTALLED ON CLOSED TANK
SYSTEMS
Installations with a closed tank:
• The installer is responsible for the correct installation of the system, which is
to be compliant with UNI standards 10683/2005 – 9615/90 – 10412:2
• All must be performed by qualified personnel according to Ministerial
Decree 37 ex Law 46/90
• The thermal relief valve (supplied by EDILKAMIN) must be connected to the
cooling circuit with a minimum pressure of 1.5 bar.
AL=P= coil power supply, always with a minimum pressure of 1.5 bar
• KITS 5 and 6 must be installed within a MAX distance of 150 cm from
the fireplace.
Litres
• Another expansion tank must be installed specifically for the thermo
fireplace in accordance with the volume of water of the system.
(an expansion tank in common with other generators is not permitted).
1 Year
•The safety and thermal relief valves must be checked at least once a year
by qualified personnel according to Ministerial Decree 37 ex Law 46/90
20

GENERAL SAFETY REGULATIONS

YES
MIN.
1,5 bar
MAX 1,5 m
?
• THE THERMO FIREPLACE MUST NEVER
FUNCTION WITHOUT WATER IN THE SYSTEM.
• THE THERMO FIREPLACE CAN BE DAMAGED IF IT
IS IGNITED WITH NO WATER IN THE SYSTEM.
• The thermo fireplace is designed to heat water by
means of wood combustion in the hearth.
• The only hazards that can derive from using the
thermo fireplace pertain to non-compliance with the
installation instructions, direct contact with live
electrical parts (inside), contact made with the fire and
hot parts or foreign substances being put in the
fireplace.
• For the thermo fireplace to function properly
installation must be carried out according to the
instructions given in this booklet and the door must
only be opened to refill the hearth with wood.
• Never put foreign substances in the hearth or in the
tank.
• No flammable products are to be used to clean the
smoke outlet channel.
• The glass can be cleaned when COLD with a suitable
product (e.g. GlassKamin) and a cloth. Do not clean
when hot.
• The exhaust pipes and the door become very hot
when the thermo fireplace is used.
• Do not place anything that is not heat resistant close to
the thermo fireplace.
• NEVER use liquid fuel to ignite the thermo fireplace or
to rekindle the embers.
• Do not obstruct the external air inlets in the room
where the fireplace is installed or the air inlets of the
thermo fireplace itself.
• Do not wet the thermo fireplace and do not go near the
electrical parts of the system with wet hands.
• Do not use reducers on the smoke exhaust pipes.
• The thermo fireplace must be installed in a place that
is suitable against fire hazards and equipped with all
that is required (power and air inlets/outlets) for it to
function properly and safely.