EdilKamin ACQUATONDO 22 Serie Manual De Instrucciones página 30

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
ELECTRONIC REGULATOR (KIT 1-2-3-5-6)
electronic regulator
IMPORTANT ADVICE REGARDING THE INSTALLATION
The connections, commissioning and verification of proper operation
of the fireplace must be carried out by qualified personnel, who can
implement all connections in accordance with the laws in force,
particularly with Italian Law No. 46/90, apart from complying with
these instructions.
Compliance with regulations regarding the earth
connection is fundamental for the safety of people.
It is obligatory to install a differential circuit breaker switch before
the device and the entire electrical circuit of the thermo fireplace.
It is also obligatory to connect the pump, valve and metal parts of
the thermo fireplace to an earthing system.
LEGEND
AA acoustic alarm switch
R
way valve opening setting (KITS 1-3-5-6)
R
circulators operation setting (KIT 2)
RIC internal pump setting
S
MAN-OFF-AUTO selector
SP pump light
SS overheating light
ST temperature scale
SV 3-way valves light (KITS 1-3-5-6)
SV circulators setting (KIT 2)
Technical Data
Power Supply (+15 – 10%)
Degree of protection
Min/Max Room Temperature
Sensor range
Thermometer
Maximum contact rating of the circulator
Maximum contact rating of the 3-way valve
Fuse
32
The electric control regulator allows you to monitor the operating
conditions and is equipped with:
- MAN-OFF-AUTO selector (S)
- temperature scale (ST)
- acoustic alarm (AA)
- 3-way valve opening setting (R) (KIT1-3)
- circulators operation setting (R) (KIT2)
- internal pump setting (RIC)
- 3-way valve light (SV) (KIT1-KIT3)
- circulators setting light (SV) (KIT2)
- overheating pump (SS)
- pump light (SP)
Operation
- Control device:
•Thermometer
- Protection device
(acoustic alarm system):
•Acoustic alarm (AA)
•Overheating alarm (SS)
This system intervenes when the water temperature exceeds 90° C and
warns the user to stop adding fuel.
The acoustic alarm can be disabled from the switch (AA).
However, the alarm remains enabled by means of the
overheating light (SS).
To restore the initial settings, the switch (AA) must be enabled after the
water temperature in the thermo fireplace has cooled down.
- Power supply device
(circulation system):
• MAN-OFF-AUTO selector (S)
• Pump light (SP)
The pump remains on when in manual mode and off when in
OFF mode. When in AUTO mode, the pump is activated by the system
when the desired temperature is reached, by means of the internal setting
(RIC), which ranges from 20 to 80° C (this is pre-set at 20° C).
- Operation device (setting system):
•3-way valve opening setting (R)
•3-way valve operating light (SV)
When the fluid reaches the temperature set through the regulator, the 3-
way valve diverts the fluid to the radiators and the operating light (SV)
goes on.
When the temperature of the fluid drops below the set value, the system
opens the electrical circuit and the 3-way valve bypasses the fluid directly
to the thermo fireplace.
Attention:
During normal operation check that the warning lights (SV) and (SP) are
lit.
fig. M
Positioning
The electronic regulator must be installed close to the thermo fireplace.
The sensor of the operation, protection and control devices must be placed
directly on the thermo fireplace or at most on the flow pipe, no more than
5 cm away from the thermo fireplace and in any case before any
Vac
230
intercepting device.
The sensor must be immersed in the well.
IP
40
Installation
The power supply must be disconnected from the mains and the
°C
0 to+50
AUTO-OFF-MAN selector (S) must be in the OFF position when
all these operations are carried out.
m
1,2
Follow this procedure to install the electronic regulator correctly: loosen
the fastening screw, remove the cover and fasten it in place against the
wall with the dowels supplied.
°C
30 to 90
Then make the connections, paying utmost attention to the wiring diagram
and pass the wires through ducts that are in conformity with the regulations
W
400
in force. Put the cover back in place and tighten the screw.
Connect the brown wire (phase) and blue wire (neutral) of the 3-way
Valve, respectively, to terminals 5 and 6 of the regulator.
W
250
Connect the yellow/green wire to the earth.
Follow
mA
500
package to connect the regulator to the system properly.
the
assembly
instructions
contained
in
the

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido