TECHNICAL DATA

Leveling accuracy
...with 90°-penta-prism
Rotation:
Operational area
Laser type:
Laser class:
Self-leveling range:
Leveling time:
Leveling indicators:
Laser beam diameter
Power supply:
Operating temp.:
Storage temp.:
Tripod attachments:
Measurements/Weight:
High temp. disconnection:
Low voltage disconnection:
1) at 21° Celsius
2) Plumb point without prism
3) under optimal atmospheric circumstances
4) along the axis
This is to certify that the construction laser (S/N Page 69) complies with the
specifications mentioned in the operating manual when leaving our facilities.
All instruments are controlled on a 100%-basis; the individual datas are
kept in our files.
The managing director
18
1,2,4
:
< ± 21"; ± 0.1 mm/m
1,4
:
< ± 42"; ± 0.2 mm/m
4 speed levels
appr. 10/80/280/800
1,3
:
appr. 330 feet (100 m) with detector
red diode laser 635 nm
≤ 1 mW, class 2
appr. ± 8% (appr. ± 4,8°)
appr. 30 sec
2 LEDs; laser blinks
1
:
appr. 5 mm near the unit
4 x 1.5V Baby cells type C (LR14)
23°F...113°F (-5°C ... 45°C)
-4°F...158°F (-20°C ... 70°C)
5/8" horizontally and vertically
180 x 150 x 130 mm / 1,9 kg
no laser beam
no laser beam
1