2. Mount the TL8055LT and its back plastic housing to the wall using the screws provided. Pass both antenna
cables through the back plastic and push the antenna ends into the module connectors to snap the antennas
onto the module.
a. For wall-mounted systems, fully uncoil both antenna cables and drop both antennas into the wall. Be
sure to check signal strength before completing installation. If signaling is poor, relocate the primary
antenna only to improve the signal strength.
b. For table-mounted systems, it is acceptable to leave some of each cable uncoiled, but be sure to sep-
arate the antennas from each other and from the panel by approximately 1 foot. If signaling is poor,
relocate the primary antenna only to improve the signal strength.
3. Connect the module to the panel via the 16 pin ribbon cable. The ribbon connector is located at the top of
the module, near the antenna. On the panel, the ribbon connector is located directly across from the con-
nector on the module.
4. Connect one end of the ethernet cable to the ethernet port on the communicator and connect the other end
of the ethernet cable to the ethernet port on the router.
5. Snap the IMPASSA front plastic housing onto the back plastic houseing to complete the mounting of the
panel.

Power up

When the module has been fully connected to the panel via the ribbon cable, perform a full power cycle by fol-
lowing these steps:
1. Connect battery leads to the battery.
2. Plug the panel power transformer into the AC outlet.
It is important to plug in the battery before closing the IMPASSA, otherwise the panel will issue a "System
Low Battery" message regardless of the battery voltage level.
Note: Power cycling will clear existing banners.
Figure 1-2 Module compartment for IMPASSA panels
SCW 9055/57 ( G, I, D Models)
Ethernet port
Mounting holes (4)
Battery
Surface mount
wiring access
AC oower
AC
AC
Cover screw hole
12 V
PGM/Zones
telephone line
DC
Aux
1 I/O 2
Ring
Tip
R-1
+
-
Red
Grn
Gra
- 9 -
Communicator
module
Wiring access
Case tamper dwitch
T-1
Brn
Alarm.com LTE