PELLET LOADING
A handy front pull-out drawer allows you to
easily load pellets at an ergonomic height
without using step ladders or stools, even
when the fireplace is on, and in compliance
with EN 14785.
The front pull-out tray is accessed via the
front grille's flip-up opening with the "cold
hand" handle (fig. E - pag. 28).
NOTE regarding the fuel.
PELLET-BLOK is designed and programmed to burn wood pellets with 6 mm diameter.
Pellets are a type of fuel in the form of little cylinders, made from compacted sawdust, compressed under high pres-
sure with no adhesives or foreign materials. They are sold in bags of 15 kg.
For the stove to function properly, you MUST NOT burn anything else in it. Using other materials (including wood)
will render the warranty null and void. Such use is detected by laboratory analyses.
Edilkamin has designed, tested and programmed their stoves to guarantee the best performance when pellets with
the following characteristics are used:
diameter: 6 millimetres - maximum length: 40 mm - maximum moisture content: 8% - calorific value: at least
4300 kcal/kg.
If pellets with different characteristics are used, the stoves must be recalibrated – a similar procedure to that carried
out by the DEALER when the stove is ignited the first time.
Using unsuitable pellets may: decrease efficiency; cause malfunctions; stop the stove from functioning due to clog-
ging, dirt on the glass, unburnt fuel, etc.
A simple, visual analysis of the pellets may be carried out:
Good quality: smooth, uniform length, not very dusty.
Poor quality: with longitudinal and transverse cracks, very dusty, various lengths and mixed with foreign matter.
Before igniting.
1st ignition: contact your local Dealer, who will calibrate the insert based on and in compliance with installation conditions.
Failure to have an authorised Edilkamin DEALER perform start-up will void the guarantee.
They will calibrate the insert according to the type of pellets available and the conditions of use.
There may be a slight smell of paint the first few times it is ignited. This will disappear quickly.
Before igniting, check:
• that installation is correct
• electricity supply
• that the door closes correctly
• that the combustion chamber is clean
• stand-by indicated on the remote control display: hours (fixed display), ambient temperature and the reserve (or kg of
pellets in the tank) will flash alternately on the display.
INSTRUCTIONS FOR USE