Positive Pressure Method — Place your
palm lightly over exhalation valve cover
and gently exhale.
P100 with Splash Guard Method -
Support the cartridge from behind using
your fingers and depress the button with
your thumb. Gently inhale so that the
facepiece collapses slightly and hold
breath for ten seconds. The facepiece
will remain collapsed while the breath is
held, unless there is a leak in the seal.
Note: If a leak is detected, adjust the straps
or reposition the facepiece, ensure the push
button is completely depressed, and repeat
test until no leakage is detected.
If any leakage is detected around the facial
seal, readjust head harness straps and
repeat test until there is no leakage. If other
than facial seal leakage is detected, the con-
dition must be investigated and corrected
before another test is made. The respirator
must pass one of the above tightness tests
before the respirator is used.
Do not enter any atmosphere with this
respirator unless you know that:
1. You have read, understood, and fol-
lowed all instructions and warnings
pertaining to the respirator.
2. The respirator and conditions meet
the requirements outlined.
3. The cartridges are the proper type for
the contaminant or contaminants pre-
sent.
4. The amount of oxygen is sufficient to
support life (that is, at least 19.5 per-
cent oxygen by volume at sea level).
Do not use if oxygen concentration
sufficient to support life is question-
able.
DESCRIPTION
WARNING
5. Respirator has passed a tightness
test. (See Test for Tightness.)
6. Filters/Cartridges do not need to be
replaced. Discard exhausted car-
tridges.
7. You are not colorblind and can distin-
guish between the beginning and end-
ing colors of the end-of -service-life
indicator (when using Mersorb or
Mersorb-P100 respirators only).
Failure to follow the above warnings can
result in serious personal injury or death.
To replace cartridges:
1. Remove the expended cartridges and
dispose of properly.
2. Remove the replacement cartridges from
storage bags.
3. Place cartridges on
connectors carefully.
Line up match-mark
on cartridge with
small lug on face-
piece connector.
Make sure cartridge
connector lugs align with the cartridge
opening. Push down and tighten car-
tridge clockwise until the stops are
engaged. To ensure a good seal against
the facepiece, tighten each cartridge by
gripping as much of the circumference of
the cartridge as possible and then slowly
turning the cartridge until tight.
To replace snap-on filters:
1. Remove snaptight filter covers and dis-
card used filter.
2. Replace with a new filter into each filter
cover; NEVER load filters into the recep-
tacles.
3. Replace filters with CAUTION as to pre-
vent damage to the filters.

CLEANING AND DISINFECTING

If the facepiece is to be cleaned, remove the
cartridges. The facepiece should be cleaned
7