Descargar Imprimir esta página

Rocal ESTELA X1043 Manual De Caracteristicas, Instalacion Y Funcionamiento página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

ALL LOCAL, NATIONAL AND EUROPEAN STANDARDS MUST BE COMPLIED WITH WHEN
INSTALLING THE APPLIANCE.
Warning: When in operation this appliance gets very hot, do not touch the appliance
without using the glove provided.
ATTENTION:
You must respect the maximum load allowed by the manufacturer of the logs as well as the
height of the recharge.
2.1. Using the appliance for the first time. For early on, and for a reasonable time, the fuel load
should not exceed 50% C.M.A.
.
(Maximum fuel load authorised by the manufacturer)
2.2. Control of combustion.
To obtain the nominal output and maximum efficiency as stated in the Technical data, operate the
appliance with these position:
Primary air control 0% open
Secondary air control 62.5% open
2.2.1. Primary and secondary air control slide
Is located on the front of the fireplace.
(21).
Primary on left, Secondary on right.
ATTENTION:
The positions indicated are according to technical characteristics table, in any case these
positions must be adapt according to the flue depression and fuel quality.
2.3. Safety distances. Combustible or fragile materials (include furniture etc.), must be positioned
at least 1000 mm from any part of appliance. It is prohibited to use the space under the ash pan to
store fuel.
2.4. Type of combustion. This fireplace is designed for intermittent use with the doors closed.
2.5. Authorised fuel by the manufacturer. Do not use the appliance as incinerator, and only use
fuels approved by the manufacturer. Use natural logs that have a moisture content between 12
and 20 %. It is highly recommended to dry newly cut wood for 2 years. Their maximum length must
not be longer than 400 mm. The use of other types of fuel is forbidden, as well as any liquid (used
to light barbecue fires).
2.6. Loading and reload fuel. Do not exceed the maximum authorized load of fuel (see table of
technical characteristics), ensure that when refuelling the fuel does not exceed 200 mm in height.
A log guard is provided.
IMPORTANT NOTE:
Interior parts vermiculite SHOULD NOT BE HIT, especially when done refueling.
If any of these parts are cracked, but is properly placed in your site, does not
alter the proper functioning of NI A POTENTIAL RISK. The device can be used
normally.
These cracks do not pose any manufacturing defects so you do not fall under
warranty.
To light the fire follow these steps: place the fuel centrally on the base of the fireplace and open
the primary air control and secondary air control to the maximum and then light the fire. (USE
ONLY THE ELEMENTS FOR THIS).
2.7. Mechanism blockage. Check all working parts, especially those that could jam after long
periods of inactivity: door handle, air controls, flue connections all operate correctly. Ensure the
exterior ventilation cannot be blocked.
2.8. Cleaning and maintenance.
2.8.1. Glass cleaning. Let the fire burn out completely before cleaning. Do not allow cleaning
product to remain in contact with the appliance surface or the rope seal as it will cause them to
corrode. Opening the door use the tool – level to be provided to this effect – place hook in the hole
and then pulling the door to us.
Página 16 de 25

Publicidad

loading