Descargar Imprimir esta página

Troubleshooting - Rocal ESTELA X1043 Manual De Caracteristicas, Instalacion Y Funcionamiento

Publicidad

Idiomas disponibles

Idiomas disponibles

3. TROUBLESHOOTING

This is a table with potential problems, the reason for them and solutions:
PROBLEM
1. Smoke leaking into
the room / Insufficient
flue draught
2. Excessively dirty
glass
3. Whitening of the
glass or damage the
color of the plate
4. Appliance produces
little heat
5. Appliance emitting
smoke / producing bad
odours
6. Excessively flue
draught
7. Cracks in some parts
of vermiculite inside
The inspection of the chimney and the installation of the appliance must be carried out by a Professional.
For any doubt consult your local Rocal dealer.
REASON
Insufficient flue draught
Insufficient air for combustion
Incorrect flue draught
Poor quality fuel.
Excess temperature caused by an
excessive fire in the combustion
chamber
Poor quality fuel
Insufficient fuel
Burning for the first time
Combustible or inflammable
elements around the appliance or
surrounding walls of the appliance
A crack in the combustion
chamber
Incorrect flue draught
Air slider not open enough
Beat in one of the pieces
performed, especially at the time
of recharge
SOLUTION
-Check that the registers
-Check that flue
-Connection – Diameter – Leaks - Insufficient
length
- Fire gone out
- Flue may be restricted and requires sweeping.
-Check the air vents, are they clear.
-Other ventilation or heating device working
simultaneously in the same or adjacent room?
Check the flue draught.
Use authorized fuel
Check the fuel load
Set the registers according to paragraph 2.2.
Use authorized fuels
Add fuel
Ventilate the room and wait for the paint to cure.
This could take several uses
Review insulation materials as fibreglass,
fireproof wood or possible combustible elements
and replace them
Check if the appliance is air tight and if a crack is
seen, do not use your appliance and contact your
dealer.
Check the flue length
Leaks
Diameter
-Check the air slider position.
-Check the mechanism operates correctly
Try not to pull the logs but put
Perform charging where the temperature of the
combustion chamber has decreased
NOTE: If the part is only cracked but does not
move from your site, you can continue using
the device with absolute normality
2.6. Loading and refueling)
(see section
Página 18 de 25

Publicidad

loading