Chapter 6. Machine adjustment and setting up

6.2.5. Alarm messages

The electronic board detects series of alarms that are indicated on the display (7) by the following messages:
"Emergency pushbutton" alarm.
A 1
Emergency pushbutton (9) is held down.
Release the button by turning it to the right. Afterwards press START button (5).
A 2
"Inverter" alarm.
Check the failure coding on the inverter display arranged on the electrical installation.
Check for the reset procedure on the inverter user manual (supplied with the machine).
A 3
"Motor Thermal Switch" alarm
Check the correct operation of the fan wheel motor.
A 4
"Temperature" alarm.
The temperature has exceeded 230°C or the probe is interrupted.
Check the probe and the relating connections.
If the alarm remains after having carried out the indicated interventions and controls to restore the
machine, contact the technical assistance.

6.3. Air flow adjustment

It is possible to adjust the air flow on the product to pack
by acting on the knobs (11).
The rotation of knobs (11) determines the position of the
flaps (12) which drive the hot air flow into the desired
direction so to obtain the best shrinking.