Table 1 Electrical And Environmental Ratings; Table 2 Dimensions; Mounting The Light - Federal Signal 371LED-120 Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para 371LED-120:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Table 1 Electrical and environmental ratings

Operating Voltage:
Flash Rate:
Maximum Operating
Current, mA:
In-rush Current:
Operating
Temperature:
Environmental
Ratings:
Height:
Diameter:
Net Weight:
Shipping Weight:

Mounting the Light

The Model 371LED-120 light is designed for mounting on a flat
horizontal surface or on a 1-inch NPT pipe. For surface mounting on
solid substrates, the separately purchased Model 371BRCKT surface
mounting bracket can be used. If conduit side-entries are to be used,
disassemble the light as described in "Wiring the Light" on page 9 and
remove one or more knockouts with a blunt tool before mounting the
light. Use a file to remove excess flash around the knockout.
INSTALLATION NOTE: To avoid moisture buildup within the
light enclosure in highly humid areas where condensation is present
in the conduit system, duct sealant or other suitable materials are
recommended for sealing the wires/conduit entrances.
Installation and Maintenance Instructions
120 Vac 50 Hz/60 Hz
60 FPM
320 mA
25.1 A for 0.63 ms
-31 °F to 104 °F (-35 °C to 40 °C)
Type 4X, IP66

Table 2 Dimensions

Model 371LED-120 Rotating Light
11.38 in (288.9 mm)
9.12 in (231.6 mm)
7.1 lb (3.2 kg)
8.1 lb (3.7 kg)
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Commander 371led-120

Tabla de contenido