24 V DC control supply and filter
MicroFlex e150 requires a 24 V DC (20-30 V DC) 1 A supply to power
the control electronics.
Connect the control supply at connector X2.
A fused DC supply should be provided for the MicroFlex e150. If other
devices are to be powered from the same 24 V supply, a filter (catalog
number FI0014A00) should be installed to isolate the MicroFlex e150
from the rest of the system. Alternatively, a ferrite sleeve may be
attached to the supply cable near connector X2.

Safe Torque Off (STO) inputs

24 V DC (12-30 V DC) must be applied to both STO inputs
to allow the drive to operate. SREF is common to both
inputs.
Digital I/O
24 V DC (12-30 V DC) general purpose digital inputs and
outputs.
Analog I/O
An analog input can be used to receive a ±10 V demand
signal from a motion controller.
The ±10 V analog output can be used to control external
devices.
Quick Installation Guide – MicroFlex e150 7
X2
SREF
STO1
SREF
STO2
X3
Status-
Status+
DOUT2-
DOUT2+
DOUT1-
DOUT1+
DIN2-
DIN2+
DIN3-
DIN3+
DIN1-
DIN1+
DIN0-
DIN0+
X3
AOUT0
AGND
AIN1+
AIN1-
AIN0+
AIN0-
Shield
Shield
X4
0V
24V