CAUTION:
• Do not exceed the current limit specified for any one receptacle.
• Do not modify or use the generator for other purposes than it is intended
for. Also observe the following when using the generator.
• Do not connect an extension to the exhaust pipe.
• When an extension cable is required, be sure to use a tough rubber
sheathed flexible cable (IEC 245 or equivalent).
When using an extension cable the resistance value shall not exceed
1.5 Ω.
• Limit length of extension cables; 60 m (200 feet) for cables of 1.5 mm
2
(0.0023 in
) and 100 m (330 feet) for cables of 2.5 mm
extension cables will lower usable power due to resistance in the
extension cable.
• Keep the generator away from other electric cables or wires such as
commercial power supply lines.
GW1 type
When connecting an angled plug, be sure to use only a IPX4 plug.