Waste Disposal - Beninca CP.J4 ESA Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
An optional accessory to power the control unit is available in the event the mains power supply is cut off.
The kit is composed of a battery charger and two 12V rechargeable batteries, fixing brackets, screws and cables.
For further information, please refer to instructions supplied with the accessory.
If the transmitter code is already stored in the receiver, the remote radio learning can be carried out (without accessing
the control unit).
IMPORTANT: The procedure should be carried out with gate in the opening phase, during the TCA dwell time.
Proceed as follows:
1 Press the hidden key of the transmitter, the code of which has already been stored in memory.
2 Within 5 seconds, press the already memorised transmitter key corresponding to the channel to be matched to the new
transmitter. The flashing light switches on.
3 Within 10 seconds, press the hidden key of the new transmitter.
4 Within 5 seconds, press the key of the new transmitter to be matched to the channel selected at item 2. The flashing
light switches off.
5 The receiver stores the new transmitter code and exits from the programming mode immediately.
Some messages that are displayed in the event of malfunctions are shown hereunder:
Error, radiotransmitter self-adjust-
ment or
err
self-learning
Error, motor
Err1
Error, photocells
Err2
Error, encoder
Err3
Triggering of the amperometric sen-
amp
sor
Triggering of the thermal switch
THRM
In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and safety) can be dis-
played. One segment of the display is linked to each input. In the event of failure it switches on according to the following
scheme.
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the horizontal segments.
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste
disposal and the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call
your installer or a specialised company.
18
EmERGENCY BATTERY
TRANSmiTTER REmoTE LEARNiNG
ERRoR mESAGES
If the error occurs during self-learning, check the STOP/PHOTO/PP/
CLOSE inputs or whether frictions occur during the door leaf stoke.
If the error occurs during self-learning of the radio-transmitters, this
means that the memory of the receiver is no longer able to receive other
transmitters or the transmitter is not compatible.
Check connections to the motor
Check connections to photocells
Check connections to the encoder
An obstacle or a point of friction has caused the triggering of the am-
perometric sensor. Remove the obstacle or check the door stroke. Act
on the PMO/PMC parameter, if required.
The control unit has switched the system to a rest status due to an ex-
cessive number of consecutive operations. If a sufficient cooling time
has elapsed, the control unit is reset to normal operation.
In the negative, a fault in the motor might have occurred, which requires
the replacing of the motor.
diAGNoSTiCS
P.P.
PHOT STOP

WASTE diSPoSAL

OPEN CLOSE
DAS

Publicidad

Tabla de contenido
loading

Tabla de contenido