3 Transport and interim storage
Inspect the pump/system for transport damage
immediately upon arrival. Any transport damage
found must be reported to the carrier within the
prescribed periods.
CAUTION! Risk of damage to the pump!
Risk of damage due to improper handling during
transport or storage.
• The pump may only be hung from or carried
using the handle provided for transport. Never
suspend or carry using the cable!
• The pump should be protected against moisture,
frost and physical damage during transport and
interim storage.
4 Applications
WARNING! Health hazard!
The materials are not designed for drinking
water supply.
• The pump must not be used for pumping drink-
ing water.
The submersible motor-driven pump is suitable
for transporting sewage from shafts and tanks. It
is used primarily for pressure drainage of sewage
water for domestic purposes (according to EN
12056 in compliance with the country-specific
prefaces and regulations).
CAUTION! Risk of damage to the pump!
The pump is not suitable for use with flow media
containing solids such as sand, stones or metals.
5.2

Technical data

Mains voltage
Frequency
Protection
Insulation class
Speed
Power input P
1
Motor power rating P
Nominal current
Winding protection contact (break contact)
Max. contact load
Permissible medium temp. Min / max
Max. flow rate
Max. delivery head
Max. immersion depth
Operating mode S3 (optimum),
motor immersed
6
1~230 V, 10 % (single-phase motor)
3~230 V, 10 % ( three-phase motor)
3~460 V, 10 % ( three-phase motor)
60 Hz
IP 68
F
Max. 3480 rpm
see rating plate
see rating plate
2
see rating plate
U
max
U
max
+37°F (+3°C) up to 104 F (40°C)
see rating plate
see rating plate
33ft (10 m)
Intermittent service S3,
25% (2.5 min. mode, 7.5 min. break).

5 Product data

5.1 Type code
Example: MTS 40/95 1-230-60-2
MT
S
40
/95
1
230
60
2
Example: MTS 40 E 95.80/20/3-460-60-2 FM
MT
S
40
E
95
80
20
3
460
60
2
FM
=250 V AC,
I
= 1 A
max
= 30 V DC,
I
=30 mA DC
max
Macerator Technologie
Stainless Steel Motor
Nominal width discharge side [mm]
( 1½ in.)
Maximum delivery head [ft]
where Q=0 gpm)
1: single-phase motor, 1~
3: three-phase motor, 3~
Mains voltage [V]
Mains frequency [Hz]
2 pole motor
Macerator Technology
Stainless Steel Motor
Nominal width discharge side [mm]
( 1½ in.)
Type of impeller: E = Single channel
impeller
Maximum delivery head [ft]
where Q=0 gpm
Maximum flow rate [gal/min]
where P
=P
2
2max
Power P
[hp] = Value / 10
2
3: Three-phase motor 3~
Mains voltage [V]
Mains frequency [Hz]
2 pole motor
FM approved (Explosion protection)