SPECIFICATIONS
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel)
CONSUMPTION RATE
ELECTRICAL DATA
ASSEMBLED DIMENSIONS
APPROXIMATE HEATING AREA
CLEARANCE TO COMBUSTIBLES

OPERATING PRECAUTIONS

This­is­a­kerosene,­direct-fired,­radiant­heater.­It's­intended­use­
is­primarily­temporary­heating­of­buildings­under­construction,­
alteration­or­repair.
Direct-Fired­means­that­all­of­the­combustion­products­enter­the­
heated­space.­Even­though­this­heater­operates­very­close­to­100­
percent­combustion­efficiency,­it­still­produces­small­amounts­
of­carbon­monoxide.­Carbon­monoxide­(called­CO)­is­toxic.­CO­
can­build­up­in­a­heated­space­and­failure­to­provide­adequate­
ventilation­could­result­in­death.­The­symptoms­of­inadequate­
ventilation­are:
•­
Headache­
•­
Dizziness
•­
Burning­eyes­and­nose­
•­
Nausea
•­
Dry­mouth­or­sore­throat
Be­sure­to­follow­advice­about­ventilation­in­the­Safety­Precautions­
section.
Forced­Air­means­that­a­blower­or­fan­pushes­the­air­through­the­
heater.­Proper­combustion­depends­upon­this­air­flow;­therefore,­
the­heater­must­not­be­revised,­modified­or­operated­with­
parts­removed­or­missing.­Likewise,­safety­systems­must­not­be­
circumvented­or­modified­in­order­to­operate­the­heater.
When­the­heater­is­to­be­operated­in­the­presence­of­other­people­
the­user­is­responsible­for­properly­acquainting­those­present­with­
the­safety­precautions­and­instructions,­and­of­the­hazards­involved.

SAFETY PRECAUTIONS

1.­
Recommended­for­use­with­No.1-K­kerosene­fuel.­Factory­tested­
for­use­with­No.2-K­kerosene,­No.1­or­No.2­Diesel,­No.1­or­No.2­
fuel­oil­or­JP8­Jet­A­fuel­and­these­fuels­may­be­used­as­well.­Never­
use­gasoline,­biodiesel,­oil­drained­from­crank­cases,­naphtha,­paint­
thinners,­alcohol­or­any­other­highly­flammable­fuels.
2.­­ Check­the­heater­thoroughly­for­damage.­DO­NOT­operate­a­
damaged­heater.
3.­ DO­NOT­modify­the­heater­or­operate­a­heater­which­has­been­
modified­from­its­original­condition.
4.­ Suitable­for­outdoor­use.­For­either­outdoor­or­indoor­use­
where­adequate­ventilation­is­provided.­Never­use­in­areas­
normally­for­habitation.­Not­for­use­where­exposed­to­weather.
5.­ Use­in­well­ventilated­areas,­provide­at­least­2­sq.­ft.­(0.19­sq.­
m.)­of­opening­near­the­floor­and­2­sq.­ft.­(0.19­sq.­m.)­near­
the­ceiling­directly­to­outdoors.­Increase­air­openings­as­marked­
for­each­additional­heater.
6.­ Always­keep­combustibles,­like­paper­and­wood­at­least­8­ft.­
from­the­heater­outlet­and­3'­from­the­top,­sides­and­inlet.­
Mr. Heater, Inc. | Kerosene Fired Radiant Heater
Model
BTU
TANK CAPACITY
RUN TIME
DRY WEIGHT
FULL WEIGHT
MH125KTFR
125,000­BTU/HR.
.96­GAL/HR.
9.25­GALLONS
10­HRS.
120v­60Hz
22.5"­X­34.5"­X­38"
66­LBS.
129­LBS.
3125­SQ.­FT.
OUTLET­8'­SIDES­3'
Locate­8­ft.­from­canvas­or­plastic­coverings­and­secure­them­
to­prevent­flapping­movement.­
7.­
Caution:­Due­to­the­high­surface­and­exhaust­temperatures,­
adults­and­children­must­observe­clearances­to­avoid­burns­or­
clothing­ignition.­Do­Not­Touch.­Keep­children,­clothing,­and­
combustible­away.
8.­ Install­the­heater­such­that­it­is­not­directly­exposed­to­water­
spray,­rain­and­/­or­water.
9.­ Never­use­in­areas­normally­for­habitation­and­/or­where­
children­may­be­present.
10.­ Always­operate­only­on­a­stable,­level­surface.­
1 1.­ Do­not­use­with­duct­work.­Do­not­restrict­inlet­or­exit.
12.­ Use­only­with­electrical­power­specified.­The­electrical­
connection­and­grounding­must­comply­with­National­
Electrical­Code­–­ANSI/NFPA­70­(USA)­and­CSA­C22.1­
Canadian­Electrical­Code,­Part­1­(Canada).
13.­ Use­only­a­properly­grounded­3­pronged­receptacle­or­
extension­cord.
14.­ Do­not­move,­handle,­or­service­while­hot­or­in­operation.
15.­ Use­only­in­accordance­with­local,­state­(provincial)­or­
national­requirements,­ordinances­and­codes.

OPERATING INSTRUCTIONS

UNPACKING
1.­ Remove­heater­from­carton.
2.­ Remove­all­protective­material­which­may­have­been­applied­
to­the­heater­for­shipment.
3.­ Check­the­heater­for­possible­shipping­damage.­If­any­
damage­is­found­immediately­contact­the­manufacturer­at­
800-251-0001.
ASSEMBLY
Handles­and­safety­guards­are­found­in­the­shipping­carton­along­
with­mounting­hardware.­
MH125KTFR
1.­ Locate­the­transport­handle­shipped­with­your­unit.­Along­
with­the­four­Phillips­headed­screws,­nuts,­and­washers.­and­
install­them­two­sets­per­side.­
2.­ Locate­the­radiant­surface­guard­shipped­with­your­unit.­
Next­locate­the­four­Phillips­headed­screws­included­with­the­
hardware­package­and­attach­the­guard­to­the­four­guard­
connection­points­located­at­approximately­the­2­o'clock,­
4­o'clock,­10­o'clock,­and­8­o'clock positions­when­looking­
at­the­front­of­your­heater.­If­located­in­Canada­you­have­
an­additional­Drape­guard­to­install­above­the­front­radiant­
surface­guard.­The­guard­and­fasteners­are­provided.­
3
Operating Instructions and Owner's Manual
MH70KTFR
70,000­BTU/HR.
.52­GAL/HR.
­2.77­GALLONS
5.34­HRS.
120v­60Hz
13.25"­X­25"­X­22.25"
40­LBS.
58.89­LBS.
1750­SQ.­FT.
OUTLET­8'­SIDES­3'