Descargar Imprimir esta página

General Characteristics - CAME Z Serie Manual De Instrucciones

Ocultar thumbs Ver también para Z Serie:

Publicidad

ENGLISH
Description of control panel
The ZC3 electric panel is suitable for
controlling the automation of series C
and F3000, 230V sliding industrial
gates, with up to 600W power and 50-
60 Hz frequency.
Wholly designed and built by CAME
S.p.A., it meets UNI 8612 regulations
in force. ABS Case with an IP54 pro-
tective level, with air recycling inlet and
transformer.
The circuit requires 230V (a.c.) at ter-
minal blocks L1- L2 and the inlet is pro-
tected with two 5A fuses, whilst the low
voltage command devices are pro-
tected by a 1A fuse.
The accessories' total wattage (24V)
must not exceed 20W.
The panel includes a manoeuvre pick-
up function. This function is activated
during the initial phase of the gate's
opening and closing.
Safety
Photocells can be connected to obtain:
- Re-opening during closure (2-C1), if
the photocells identify an obstacle
while the gate is closing, they will
reverse the direction of movement until
the gate is completely open;
- Re-closing during opening (2-CX, see
dip n°8 to OFF - 9 to OFF), if the
photocells identify an obstacle while
-4-

GENERAL CHARACTERISTICS

the gate is opening, they will reverse
the direction of movement until the
gate is completely close;
- Partial stop, shutdown of moving
gate, with activation of an automatic
closing cycle (2-CX, dip n°8 OFF - 9
ON);
- Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control
must be actuated to resume
movement.
N.B : If an NC safety contact (2-C1, 2-
CX, 1-2) is opened, the LED (pag.12
-n°8) will flash to indicate this fact;
- Obstacle presence detection. When
the motor is stopped (gate is closed,
open or half-open after an emergency
stop command), the transmitter and
the control pushbutton will be
deactivated if an obstacle is detected
by one of the safety devices (for
example, the photocells);
- Safety test function. The control unit
will now check the safety system every
time an opening or closing command is
given (see p.18).
Accessories which can be
connected to this unit
- Cycle lamp. The lamp which lights the
manoeuvring zone: it remains lit from
the moment the doors begin to open

Publicidad

loading

Este manual también es adecuado para:

Zc3