Installation

6.4 Electrical connection

DANGER OF ELECTROCUTION
Make sure that the power supply box is disconnected before carrying out any electric connection
operation. If it is connected to the mains, make sure that the main external power switch is off.

6.4.1 Power supply box connection

To wire the power supply box, follow the steps indicated below:
1. Strip 40 mm of the two wire cable on the end to be connected, stripping the two cables enough to be
able to crimp the terminals to the copper wire at the same time.
2. Pass the cable through the corrugated tube and then through the corresponding bushing.
3. Connect the terminals to the connection strip.
4. Connect to the strip.
A: Magnetothermal protective device of the safety extra-low voltage (SELV) circuit

6.4.2 Control box location

To carry out the control box electrical wiring, follow the steps indicated below:
1. Strip 40 mm of the two wire cable on the end to be connected, stripping the two cables enough to be
able to crimp the terminals to the copper wire at the same time.
2. Make a hole, bearing in mind the configuration and the route chosen for the power cable conduit, on
the bottom or left-hand side of the motor cover using a drill with a conical bit.
16/196
Fig. 10: Power supply box connection.
30VDC
A
Instructions Manual Waterlift rev.0.7 -06/09