Declaration of conformity
The filter system is tested in accordance with
Standard NSF/ANSI 58 for reduction of pentavalent
arsenic, barium, cadmium, mercury, selenium, ra-
dium 226/228, trivalent and hexavalent chromium
and lead as well as nitrates/nitrites. The results
have been confirmed by laboratory tests. The water
purifier is tested in accordance with Standard NSF/
ANSI 42, 53 for reduction of chlorine and volatile
Installation
Safety information
Risk of electric shock!
–
The statutory regulations of the respective coun-
try, as well as those of the local electricity and
water suppliers must be adhered to.
–
Only install the appliance in accordance with the
local rules and regulations.
–
First connect to the water connection and drain,
then connect the electrical power supply.
–
The Water Purifier must be disconnected from
the mains power network during installation.
–
Make sure that the house's electrical earth/
grounding system is installed in accordance with
the regulations.
–
Do not use extension cables.
–
Only plug into a separate electrical socket. Do
not share electrical outlet with other devices.
–
The Water Purifier has only to be installed in a
frost-free room.
–
Protect plastic parts and cables from high
temperatures.
–
Only connect to a cold tap water line.
–
Only connect to a water supply that meets
the regulatory requirements of the respective
country.
–
Only erect in hygienically clean areas.
28
en
organic compounds, including laboratory testing
which has confirmed the results. This appliance is
approved for the treatment of supply water concen-
trations of up to a maximum of 27 mg/l nitrates and
3 mg/l nitrites (combined) and is approved for water
pressure of 0.14 MPa – 0.83 MPa.
–
Do not subject the appliance to shaking, vibra-
tions or jolts.
–
Do not erect in the vicinity of a heating source,
or place in direct sunlight, or install in rooms
that are very moist.
–
Erect the appliance away from flammable gases
or combustible materials.
–
Make sure that there is sufficient air circula-
tion. Do not erect in closed cabinets, closets or
lockers.
–
A minimum distance of 10 cm must be main-
tained between the appliance and any wall/ob-
ject. Maintain free space around the filter cover
to allow for filter changes.
–
Only set the Water Purifier on a level, flat surface
that is designed to support such a weight.
–
The electrical plug must be freely accessible after
erection of the appliance.
–
Unpack the appliance and check for transport-
related damage.
–
Please dispose of the packaging, and if appli-
cable, the old appliance in an environmentally-
friendly manner.