Important
The total length of the entire hose set is limited to a
maximum of 5 m. The waste water connection must
be located below the appliance level. The height
difference to the connection at the appliance must
not exceed a maximum of 25 cm. Make sure that
the hose set (11) is not bent or pinched. The flow of
water must not be impeded.
Always use a new hose when replacing the Water
Purifier. Do not reuse the current hose.
Waste water connection (DW03500 only)
Use the enclosed parts to connect the waste
water hose blue (11b) to the drain connection of
the siphon. If needed, install the siphon with a
drain connection.
Water connection
Close the main tap of the house water supply.
Connect the connection valve (6c) to the cold
water line of the house water supply (see fig-
ures a and b).
a
en
b
6a
6c
6a
Important
Do not under any circumstances connect to the
warm water supply.
DW03500 only: If needed, use the enclosed adapter
(6a) (see figure b).
Close the connection valve (6c) (see figure c).