Descargar Imprimir esta página

C3 C4 C6 C43 C48; C3 C4 C5 C6 C43 C48; Sanicompact; Saniceramic - SFA SANICOMPACT LV Eco Manual De Instalación

Ocultar thumbs Ver también para SANICOMPACT LV Eco:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
UK
Fully illustrated step by step instructions are
downloadable on www.saniflo.co.uk
1
DESCRIPTION

SANICOMPACT

®

/SANICERAMIC

ned with an integral pump/macerator. SANICOMPACT
SANICERAMIC
®
is for domestic use.
Installed and used correctly, SANICOMPACT
SANICERAMIC
®
will give consistent and reliable service.
Please note the following warning signs:
«
» Possible danger to personnel,
«
» Warning of possible electrical hazard.
«WARNING» This is a general warning that failure to
follow instructions could result in poor functioning
of the unit.
OPERATION
SANICOMPACT
/SANICERAMIC
®
electronic program. It has 2 functions:
• It has a macerating and pumping function. To start, press
one of the two grey sections (light grey: short flush, dark
grey: long flush) of the flush button integrated to the bowl.
• It will pump away the waste water from a washandbasin.
In this case, the motor will activate automatically when
the water enters.
2
LIST OF ACCESSORIES INCLUDED
3
DIMENSIONS
4
TECHNICAL DATA
discharge of a WC
Applications
discharge of a washbasin (option)
Type
Maximum Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption
Electric Class
Degree of protection
Maximum water temperature
Net Weight
C3
C5
C6
C43/SANICERAMIC 1
C48
C4
WARNING:
Only installations conforming to the above
specifications are acceptable.
5
PERFORMANCE CURVE
6
INSTALLATION
6a
ATTACHING THE TOILET TO THE FLOOR
Find a suitable location, place the SANICOMPACT
SANICERAMIC
®
on the floor. Mark the perimeter of the bowl on
the floor and mark where the bracket screws will be, (rear
screw holes). Remove the bowl. Measure 5/8 inch (15 mm)
inwards from the line and mount the L-brackets on the
floor.
Note:
To reduce noise level when the toilet is installed on a
hard floor, you may want to insert an insulating material
between the floor and the bowl.
®
is a WC specially desig-
/
®
/
®
is operated by an
®
CLV50
3 m
220-240 V
50 Hz
800 W
4 A
I
IP44
35°C
28,6 Kg
29,0 Kg
26,5 Kg
23,2 Kg
25,4 Kg
22,0 Kg
/
®
6b
CONNECTION OF THE DISCHARGE
1 - Fully insert the elbow
H
waste tube, after turning it to face in the desired
direction.
2 - Fix the base of the elbow
rubber waste tube with a clamp
3 - Connect the sleeve
H
b
the clamp
. Cut off the end of the sleeve to adapt it
D
to the waste pipe. Connect the 32mm wastepipe into
the sleeve and secure with jubilee clip
4 -
Warning:
Ensure that you do not twist the discharge
pipework inside the unit.
5 -
Warning:
Horizontal pipe runs must have a minimum fall
of 1:100 (10mm per meter) to the soil stack.
If a vertical lift is required, it must be made before the
horizontal run at the start of the piperun.
6 -
Warning:
Protect pipes against freezing with appropriate
insulation. If the toilet is installed in an unheated loca-
tion during freezing periods protect it as follows:
• Shut off the water supply,
• Activate one cycle without water,
• Pour antifreeze in the bowl (2 litres),
• Flush the toilet.
7 -
Warning:
Any bends in the discharge pipe run should
be smooth radius bends. If using plastic pipe two 45
degree offsets can be used to form a smooth bend.
8 -
Note:
We would recommend that a drain-off point is
installed to allow the discharge pipework to be drained
down before any service work.
9 -
Note:
To avoid siphoning, install a an anti-siphon valve
at the high point of the installation.
6c
CONNECTION OF A WASH BASIN (OPTION)
If your SANICOMPACT
®
/SANICERAMIC
receive the waste water from a wash basin
(Warning: special order).
Make the connection as shown on fig.
6d
CONNECTION TO THE WATER SUPPLY
Connect to the water supply with an isolation valve.
Also it is very important that you fit a single check valve
between the Sanicompact and the water supply. This is a
Water Regulations requirement.
Caution: The quality of the rinsing of the bowl depends on
the water pressure.
WARNING:
for a correct rinsing, the water pressure
should be at least 25 PSI (1,7 bars).
Note:
In an area where water is not pure (dirty, sandy), we
advise you to add a filter between the shut off valve and
the toilet to prevent clogging of the solenoid valve.
6e
CONNECTION TO THE ELECTRICAL SUPPLY
The electrical installation should be carried by a
qualified person.
All wiring must conform to BS7671, 1992 requirements
for electrical installation. The unit requires a 220/240 V
single phase AC 50 Hz supply (UK specification). Do not
connect the unit to a conventional plug and socket. The
unit should be connected to a fully earthed electrical
supply (class 1).
It must be wired into an unswitched fused fixed wiring
connector protected by a 5 amp fuse and a residual
current detector (30 mA). This connection must be used
exclusively for supplying the unit.
The wires in the mains lead are coloured in accordance
with the following code:
Brown
Blue
Green/Yellow
in the end of the rubber
a
and tighten it on the
H
a
.
D
to the end of the elbow with
.
C
®
is equiped to
to
.
1
3
Live
Neutral
Earth

Publicidad

loading

Este manual también es adecuado para:

Saniceramic lv eco