Each of the four selection buttons is fitted with its own
"empty" warning lamp; when loading the first can the
warning lamp corresponding to the selection button is
switched off.
Fig. 6
1 - Inlet to product chutes
2 - inserts to vary the height of cans
3 - Release unit
4 - "Empty" micro-switch
5 - Limit micro-switch
COLUMNS
The columns, according to the width, can be either double
or single; for the double columns the rows of products must
be loaded in alternation, right and left (see Fig. 7).
Fig. 7
1 - Double column
2 - Single column
3 - Rotor
The columns can be preset for dispensing 66 dia. cans or
round bottles with a diameter range of 62 to 73 mm.
Warning: glass bottles can be dispensed only from
single columns.
© by NECTA VENDING SOLUTIONS SpA
According to the height, the column can be set for loading
products in single, double or quadruple row (see Fig. 8).
Fig. 8
When dispensing some types of bottles, special guides
may need to be used to keep the bottles correctly posi-
tioned.
Fig. 9
1 - Bottle guides for single column
It is essential to know exactly for which product and
how the column was set to be able to load it correctly.
Each column is fitted with its own "empty" warning device.