B.- Measuring Attenuation Test.
1.-
Connect the PROLITE-105 in a source node of the transmitting optical
network, such in a free strip of the general telecommunication cabinet at the
building.
2.-
Keep the PROLITE-105 in SIMULTANEOUS mode. The source generates
simultaneously the same wavelength (1310 nm, 1490 nm and 1550 nm).
3.-
Connect the PROLITE-67 in a receiving node of the optical network that you
want to measure, such as a UAP (User Access Point).
4.-
Activate the ATTENUATION TEST function on the PROLITE-67.
5.-
Check the measurement and store it on the memory of the device by pressing
the key
6.-
Repeat the previous step for each one of the access points (see Figure B).
C.– Printing the Certification Report.
1.-
Connect the PROLITE-67 to the PC where you have installed the control
software.
2.-
Run the control software.
3.-
Click on the ICT Test tab.
4.-
Click on the Receive loggers from the equipment button.
5.-
The lower right window shows the loggers stored on the instrument.
6.-
Select some records for making a report.
7.-
Click on the CERT icon that is on the right of the data record.
8.-
Fill in the information and click on Generate Certificate.
9.-
It generates a ICT certification report in PDF format that is saved by default in
the Certificates folder or in a folder selected by the user (see Figure C).
Page 48
.
USER'S MANUAL. PROLITE-67
07-2012