Maintenance and care

Warning
Uncontrolled moving masses can cause injury to people or damage to property (squeez-
ing). If a toothed belt breaks in combination with a vertically or diagonally installed EGC,
the work mass will fall down.
• In case of signs of wear, return the EGC to Festo for repairs.
Controller signals can cause the EGC to make unintended movements.
• Switch off the controller for all maintenance work on the EGC and secure it to pre-
vent it from being restarted unintentionally.
On cleaning and maintenance:
• If required, clean the guide axis with a soft cloth. All media gentle to the material may be used as
cleaning agents.
Note
The lubrication interval S
• Cut the lubrication interval S
present:
– dusty and dirty environment
– nominal strokes 2000 mm
– at speeds 2 m/s
– positioning profile Z delta operation (frequent acceleration and braking)
– ambient temperatures 40 °C
– product has been in operation for 3 years.
If several situations occur simultaneously, the lubrication interval must be divided by
four.
• Grease the following components:
Lubricating point (
Fig. 1)
Lubrication interval
2)
Grease
1) Or if the component no longer has a layer of grease
2) Grease gun, blast pipe and grease (
Tab. 6
Festo – EGC-TB-KF, EGC-HD-TB – 1112a English
is dependent on the product load.
int
(
Fig. 12) in half if the following situations are
int
Bearing guide
Lubrication hole aB
(
Fig. 12)
Roller bearing grease
"Accessories")
Guide rail
Surface 5
1)
As required