.9.. 3rd.LEVEL.PROGRAMMING
The rd level programming is only used in the case of advanced customisation of the function logics already present in the
memory.
Before.making.changes.at.this.level,.be.sure.you.fully.understand.the.nature.of.the.steps.you.wish.to.modify.
and.their.effect.on.the.automated.system.
To access rd LEVEL PROGRAMMING, press push-button F and, while holding it down, press push-button + for about 10
seconds. Use of the F, + and - keys is the same as for the other two programming levels.
3rd LEVEL PROGRAMMING
Function
D.
0 1
If you enable this function, automatic closure occurs after pause time.
02
If you enable this function, operation is with two different inputs: OPEN for opening and
CLOSE for closing.
Activation of recognition of the levels of the OPEN and CLOSE inputs (command
maintained). That is to say, the board recognises the level (for example, with OPEN
03
maintained and STOP pressed, on release of the latter the automated system continues
03
to open). If
is disabled, the board commands a manoeuvre only if the input is
varied.
04
Activation of DEAD MAN opening (command kept pressed). If the OPEN command is
released, operation is stopped.
If you enable this function, an OPEN command during opening stops the movement.
05
06
no
If parameter
is
06
Y
If parameter
is
06
If you enable this function, an OPEN command during opening reverses movement.
05
If parameters
and
07
If you enable this function, an OPEN command during the pause stops operation.
07
If parameters
and
08
If you enable this function, an OPEN command during the pause causes closure.
07
If parameters
and
09
If you enable this function, an OPEN command during closure, stops operation, otherwise it
reverses movement.
10
DEAD MAN closing enabled (command kept pressed). If you release the CLOSE command,
operation is stopped.
1 1
If you enable this function, a CLOSE command has priority over OPEN, otherwise OPEN
has priority over CLOSE.
12
If you enable this function, a CLOSE command commands closure when it is released.
Until CLOSE is enabled, the unit remains in closure pre-flashing.
If you enable this function, a CLOSE command during opening stops operation, otherwise
13
the CLOSE command commands reversing immediately or at end of opening (also see
14
parameter
)
If you enable this function, and if parameter
14
immediate closure at end of opening cycle (memory stores CLOSE). If parameters
14
no
and
are
CLOSE commands immediate closure.
15
If you enable this function, when the system is stopped by a STOP , a subsequent OPEN
command moves in the opposite direction. If parameter
If you enable this function, during closing, the CLOSING SAFETY DEVICES stop movement
16
and allow resumption of movement when disengaged, otherwise they immediately rever-
se at opening.
If you enable this function, the CLOSING SAFETY DEVICES command closure when
17
disengaged
(also see parameter
If you enable this function, and if parameter
18
to end before executing the closing command supplied by the CLOSING SAFETY
DEVICES.
19
If you enable this function, during closing, LOOP2 stops movement and allows it to
resume at disengagement, otherwise it immediately reverses at opening.
20
If you enable this function, LOOP2 commands closing when it disengages (also see
parameter 21).
2 1
If you enable this function, and if parameter
to end before executing the closing command supplied by LOOP2.
22
If you enable this function, LOOP1 commands have priority over LOOP2 commands.
10 secs
the system is ready for opening.
the system is ready for closing.
06
are no OPEN has no effect during opening.
08
are no OPEN recharges pause time.
08
are no l'OPEN recharges pause time.
13
is no, the CLOSE command commands
18
).
17
is
20
is
15
no
is
t always closes.
Y
, the unit waits for the opening cycle
Y
, the unit waits for the opening cycle

Setting
Y
= automatic closure
no
= disables
Y
= operation on two inputs
no
= disables
Y
= recognition of level
no
= recognition of the
change in status
Y
= enables
no
= disables
Y
= at opening stops movement
no
= disables
Y
= at opening reverses
no
= disables
Y
= in pause stops movement
no
= disables
Y
= in pause closes
no
= disables
Y
= stops
no
= reverses
Y
= enables
no
= disables
Y
= enables
no
= disables
Y
= closes when released
no
= closes at once
Y
= CLOSE stops movement
no
= CLOSE reverses
Y
= closes at the end of
13
opening
no
= immediate closure
Y
= moves in the opposite
direction
no
= always closes
Y
= closes at disengagement
no
= immediate reversing
Y
= closure when FSW
disengaged
no
= disables
Y
= closes at the end of
opening
no
= disables
Y
= closure at disengagement
no
= immediate reversing
Y
= closes if LOOP is free
no
= disables
Y
= closes at the end of opening
no
= disables
Y
= enables
no
= disables