Lenze E94AYCEO Instrucciones Para El Montaje página 48

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

8
Diagnostics
LED status displays
CIP status displays
CIP status displays are shown by the LEDs MS and NS.
LED
Colour / status
Green
MS
Off
Off
Off
On
48
Description
Red
Off
CIP module status: "Nonexistent"
The communication module is not supplied with voltage.
On
CIP module status: "Major Unrecoverable Fault"
An unrecoverable error in the communication module has occurred.
The status is set if the pending status determining device error
shows the "System fault" response.
Blinking
250 ms
250 ms
CIP module status: "Major Recoverable Fault"
A recoverable error in the communication module has occurred.
The status is set if the pending status determining device error
shows the "Fault", "Trouble", "Quick stop by trouble", "Warning
locked", or "Warning" response.
Off
CIP module status: "Operational"
The communication module is working correctly.
l
E94YCEO001E
EDK94AYCEO DE/EN/FR/ES/IT 2.0

Publicidad

Tabla de contenido
loading

Tabla de contenido