6 - WARNINGS AND
CAUTIONS
Do not use detergents, thinners, solvents etc. for scheduled mainte-
nance.
Cleaning is limited to non-live parts and must be performed by using
neutral or biodegradable products, or with the power cable unplugged.
Scheduled maintenance must be performed by qualified person-
nel or at least by suitably informed and trained personnel, with the neces-
sary mental and physical requirements, and in full compliance with the
instructions indicated below and with the Safety and Health Regulations
in force.
It is strictly forbidden to place and/or leave tools or anything else
on the machine which may be detrimental to people's safety or the
integrity of the machine.
Changes and tampering (even slight), as well as the use of non
original spare parts, exempt the Manufacturer from any liability for da-
mages of any kind and cause the warranty to expire.
Use drinking water only.
N.B.: Do not use hot water.
It is essential to supply the machine with water treated by a descaling
device, which guarantees the compliance with the abovementioned
limitations. Make sure the water network provides drinking water, with
pressure ranging between 1 and 8 Bars.
7 - GENERAL PRECAUTIONS
• Before using the appliance, always make sure that the con-
tents of this manual have been thoroughly understood befo-
rehand. Failure to comply with the instructions in this manual
exempts the Manufacturer from any liability for damages of
any kind caused to persons and/or property.
• Keep this edition for future reference.
• If installing for the first time, check beforehand for complian-
ce with the minimal safety regulations, placing and operability
of the machine, by taking note of environmental conditions
(temperature, humidity, light) and the suitability of the working
space.
• Any damage to the power cable requires Authorized Techni-
cal Assistance or a maintenance technician.
• Do not use the machine outdoors.
• In the event of failure, always ask the maintenance techni-
cian for assistance.
• Do not use water jets to clean the machine.
•
6
•
8 - INFORMATION ABOUT
THE MACHINE
8.1
Identification data
Plate (A) displays the following machine identification data:
• Manufacturer and marking
• model
• Serial no.
• year of manufacture
• supply voltage (V) and frequency (Hz)
• power consumption (W)
• number of phases of the electrical power line
• permitted pressure in the water network (MPa)
IMPORTANT
When contacting the Authorized Customer Service Centres,
please indicate model and serial number of the machine.
8.2
Technical features
Power supply voltage .................... 240V 60Hz
Power cable length ....................... mm 1.700
Installed power .......................... 5500 W
Water pressure ......................... MPa0.1÷0.8 (1÷8 bar)
Weight .................................... kg 66
IMPORTANT
The machines are programmable for any type of dispensing
dosage. Most of the electrical components are supplied with
24 VDc.
8.3
Overall dimensions
P
F. 2
h
L
L
P
h
745
550
625