Function F0 - Manual Operation; Function F1 - Query The Temperature In The Driver's Cab; Function F2 - Program The Operating Period; Function F4 - Automatic Operation - Man Cooltronic G2.5 Instrucciones De Manejo Y De Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
2.1.2 Function F0 – manual operation
EN
F0 appears in the display.
Setting the temperature and blower speed at
the control unit
Set a temperature value between 15 ºC and
27 ºC or 59 ºF and 71 ºF by briefly pressing the
or
button. The set temperature value
appears in the display.
Set a blower speed V1, V2, V3, V4 or V5 by keep­
ing the
or
ting the blower level is shown in the display.
2.1.3 Function F1 – query the temperature
in the driver's cab
F1 appears in the display, the current tempera­
ture in the driver's cab is then displayed.
2.1.4 Function F2 – program the operating
period
F2 appears in the display. The operating period
can be set for a period of 1 to 9 hours by press­
ing the
or
ON / OFF
button to confirm the set operating
period.
2.1.5 Function F4 – automatic operation
F4 appears in the display. With this function the
air­conditioning system controls the tempera­
ture automatically by adjusting the blower
speed.
Setting the temperature at the control unit
Set a temperature value between 15 ºC and
27 ºC or 59 ºF and 71 ºF by briefly pressing the
or
button. The set temperature value and
CA (automatic operation) are shown alternately
in the display.
20
button pressed. During the set­
button briefly. Press the
Operating Instructions | Cooltronic G2.5 Hatch
2.1.6 Function F6 – display °C or °F
F6 appears in the display, the display then
switches to °F.
To switch to ºC display, with the air­conditioning
system switched off, press the
keep it pressed until
As soon as
is no longer flashing press the
button.
Note
During this process the remote control is disa­
bled and must be activated again.
2.2

Other possible displays

Lb Battery almost empty.
E2 Electric fan or blower – fault.
E3 Compressor – fault.
E5 Overheating of compressor electronic
module.
E6 Frost protection sensor – incorrect contact
or defect.
E9 Compressor protection – cab overturned.
E0 Temperature sensor, return air – faulty con­
tact or defective.
EC Communication cable – fault.
Note
If E2 / E3 / E5 / E6 / E0 or EC is displayed, go to
an authorised MAN workshop.
81.0000.95.2936 | EN | 10.2019