PP

8.3 Cleaning the wire guide

 See Fig. 2 on page EN-8
WARNING

Risk of injury

Serious injuries caused by parts swirling around.
• When cleaning the wire guide with compressed air, wear suitable protective equipment,
in particular safety goggles.
1 Unscrew the cable assembly on the machine side and bring it into a stretched position.
2 Unscrew the nut (6) and pull out the liner (8) or PA liner and replace it, if necessary.
3 Clean wire conduit (3) from both sides with compressed air.
4 Slide adjusted liner or PA liner into wire conduit (3) and secure it with
the nut (6).
5 Connect cable assembly on the machine side to the wire feed unit.

8.4 Cleaning the torch neck

1 Remove gas nozzle.
2 Remove welding spatter and spray gas nozzle with ABICOR BINZEL anti-spatter agent.
3 Check wear parts for visible damage and replace them, if required.
4 Replace neck liner or wire guide when worn or soiled.
5 Clean the separating point and grease O-rings with silicone-free sealing grease.
9 Disposal
NOTICE
• Do not dispose of the device with household waste.
• For disposal, observe the local regulations, laws, provisions, standards and guidelines.
BAL.0212.0 • 2018-07-16
9 Disposal