10 Troubleshooting
5 Mark the PA liner (3) directly in front of the rollers and disconnect the central connector
again.
6 Use the ABICOR BINZEL cutter (5) to cut off the PA liner (3) where marked.
7 Sharpen the interface to 40°.
9.4 Cleaning the wire guide
WARNING
Risk of injury
Serious injuries may be caused by parts swirling around.
• When cleaning with compressed air, wear suitable protective clothing, in particular safety
goggles.
1 Unscrew the cable assembly on the machine side and lay it out in a stretched position.
2 Unscrew the nut and pull out the liner.
3 Clean the wire conduit from both sides with compressed air.
4 Slide the adjusted liner into the wire conduit and secure with a nut.
9.5 Cleaning the torch neck
To increase the system availability of the welding robot, ABICOR BINZEL offers automated
torch cleaning.
1 Remove the gas nozzle.
2 Remove the welding spatter and spray with ABICOR BINZEL anti-spatter fluid.
3 Check the wear parts for visible damage and replace them if necessary.
4 Replace the equipment kit when worn or soiled.
5 Clean the separating point and O-rings with silicone-free seal grease.
6 Test the TCP in the alignment jig after every use or following a collision.
10 Troubleshooting
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and
damage to the device. The product warranty will be rendered invalid if work is carried out on
the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
Please observe the attached document "Warranty". In the event of any doubts and/or
problems, please contact your retailer or the manufacturer.
EN - 16
MIG/MAG ROBO welding torch
BAL.0046 • 2019-02-07