DeVilbiss SleepCube AUTOADJUST PAP Serie Manual Del Usuario página 22

Dispositivo de presión positiva en las vías respiratorias
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Display Example
Set Pressure
10.0 cmH
O
2
Delay Time
45 minutes
Delay Pressure
5.0 cmH
O
2
Tubing Length
1.8 m (6 ft)
SmartFlex Menu
Press 
Enable Menu
Press 
LCD Contrast Adj
50 %
Compliance Meter
123456.7 hours
Hourmeter
HD123456
Firmware Version
V0.19 21/08/2009
Serial Number
HD123456
Adherence Score
83% (25/30)
SmartCode
F6CD-37F-357R
SmartCode
3CCC-377D-7J7X
SmartCode
30-Day
DWY4-3DB7-DJ7L
SmartCode
90-Day
752TT-47DB-7DT7C
SmartCode
Usage
ZDN-79FK-K7H
NOTE- If the unlocked symbol is shown, you are able to adjust this setting. If the locked symbol is shown, this setting can
only be adjusted by your provider.
EN - 22
Description
This is a prescription setting which controls the operating pressure.
Selectable delay time setting. Your provider has set the delay time.
This is a prescription setting which controls the operating pressure
during the delay time.
The standard tubing length supplied with the device is 6 ft. (1.8 m).
However, you can adjust your device to accommodate an air supply
tubing length of 10 ft. (3.0 m). Replacement tubing can be obtained
through your home care provider (part numbers listed at the end of this
manual).
Pressing the down key enters the SmartFlex menu. Refer to SmartFlex
Menu section for details
Pressing the down key enters the Enable menu. Refer to next section
for Enable Menu details.
This setting changes the contrast for the LCD display. This only needs
to be adjusted if you find it difficult to see the display from your viewing
angle.
The total number of hours (in 1/10 hour increments) that the device has
been providing therapy.
The total number of hours (in 1/10 hour increments) that the device has
been in operation.
Shows version of installed firmware.
Shows the serial number of the device.
Shows the maximum adherence achieved for any period of thirty
consecutive days of use within a ninety-day time frame. The score
represents the percentage of days, within thirty consecutive days, where
usage met or exceeded the 'Usage Threshold.'
SmartCode data is used for therapy management reporting. Therapy
1-Day
information is encoded in a series of letters and numbers and includes a
special character for error checking to ensure accuracy. Use the UP
7-Day
arrow or DOWN arrow keys to change the SmartCode reporting period.
There are five levels of SmartCode data: 1-day, 7-day, 30-day, 90-day
and Usage. Use UP or DOWN button to change between levels.
Mode
CPAP Mode
All
CPAP Mode
All
All
All
All
All
All
All
All
All
SE-DV54-1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sleepcube autoplus dv54Dv53 standard serieDv53 plus serieDv53 cpap serieAutoadjust cpap dv54 serieSleepcube autoadjust cpap serie ... Mostrar todo

Tabla de contenido