Descargar Imprimir esta página

Programming Overview - iVision HAD MS 400V Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31

Programming Overview

3-9
Menu-
Menü-
No.
Nr.
Entry
Selection
point
Punkt
1
1
Motor pump overcurrent
0
0,0 A
1
2,6 A
2
3,2 A
3
3,8 A
4*
4,4 A
5
5,0 A
10
6
5,6 A
7
6,2 A
8
6,8 A
9
7,4 A
10
8,0 A
11
8,6 A
12
9,2 A
Automatic time
0
3 s
1*
5 s
2
7 s
3
9 s
4
11 s
13
5
13 s
6
15 s
7
20 s
8
25 s
9
30 s
Wheel chock
0*
0*
Without wheel chock
15
15
1
1
With wheel chock
Operating options
0
Door - dock leveller mutual interlocking
1
Without door - dock leveller interlocking
17
2
Door - dock leveller interlocking without sensor
3
Dock leveller interlocking when door is not open
4*
Only dock leveller operation
5
Only door operation
- -
Exit menu
2
Shelter
0*
off
20
1
inflatable shelter
Delay time door closed
0 - 4
0* = 0 s ; 1 = 5 s ; 2 = 10 s ; 3 = 15 s ; 4 = 20 s
21
4 - 8
5 = 25 s ; 6 = 30s; 7 =35 s; 8 = 40 s
9 - 12
9 = 45 s ; 10 = 50 s ; 11 = 55 s ; 12 = 60 s
Delay time door open
0 - 4
0* = 0 s ; 1 = 5 s ; 2 = 10 s ; 3 = 15 s ; 4 = 20 s
22
4 - 8
5 = 25 s ; 6 = 30s; 7 =35 s; 8 = 40 s
9 - 12
9 = 45 s ; 10 = 50 s ; 11 = 55 s ; 12 = 60 s
- -
Exit menu
Menu
30-
37
Item
1x
Menu-
No.
Entry
Selection
point
3
Setting the door's top end-of-travel position
30
Change of direction (press for 5 sec.)
31
Setting the door's bottom end-of-travel position
50*
Fine adjustment of top end-of-travel position
33
50 - 0
0... 80mm deeper
50 - 99
0... 80mm higher
50*
Fine adjustment of bottom end-of-travel position
34
50 - 0
0... 80mm deeper
50 - 99
0... 80mm higher
Selecting the closing edge
Measuring value display (press for 5 sec.)
0
Optical closing edge OSE
35
1*
Electrical safety edge 8K2
2
Pressure wave edge DW with testing
3
Electrical safety edge 8K2 with slack rope switch
Selecting the photocell
0*
without photocell
1
2-wire photocell Ls2
2
4-wire photocell Ls5, Reflection photocell
36
3
Photocell LS2, frame fitted
4
Photocell LS5, frame fitted reflection photocell
5
2-Drahtlichtschranke Ls2, with stop during Open
6
4-Drahtlichtschranke LS5, with stop during Open
25*
Adjustment pre-limit switch safety edge
37
25 - 0
0... 50mm deeper
25 - 99
0... 100mm higher
- -
Exit menu
Selecting the operating modes
4
0
Dead man OPEN / Dead man CLOSE
40
1
Impulse OPEN / Dead man COSE
2*
Impulse OPEN / Impulse CLOSE
Response of safety edge
0*
Full reversing
41
1
Partial reversing
Correcting the slowing-down path
42
0
off
1*
on
Level adjustment
0*
off
1
Advance end stop by closing edge
43
2
activated for 200 cycles
3
activated for 1000 cycles
4
active without limitation
Enter
* Factory settings
GB
Exit

Publicidad

loading

Este manual también es adecuado para:

Had ms 230v