ENABLE BOILER CHRONO
The menu allows to enable or disable the boiler chrono function used to satisfy the domestic hot water storage tank requests in some time periods pre-established by the user.
For programming of the time periods and the explanation of the menu, see SET BOILER CHRONO sub-chapter.
BOILER CHRONO
ON/OFF
BOILER SETTING
The menu allows to set the boiler in the BIOMASS mode, the boiler functions exclusively without managing other auxiliary boilers present in the system; BIOMASS/AUX, where the
boiler can also manage an auxiliary boiler or AUX where the pellet boiler is excluded from functioning to leave just the auxiliary to function.
BOILER SETTING
BIOMASS, BIOMASS/AUX, AUX
STATUS MENU
As well as the normal standard settings, thanks to the use of the additional board, the menu o ers the following further possibilities:
Boiler status (dhw storage tank)
heating status
pu er status
BOILER STATUS
The menu allows verifying the boiler status, the maximum and minimum temperature setting, the upper and lower temperature limits of the storage tank in real time and the status of the
relative output.
STATUS
BOILER STATUS
Press key P6
press P2 until ADJUSTMENTS SET is displayed.
Press P6 to con rm
press P2 until BOILER CHRONO is displayed.
Press P4-P5 to enable or disable
Press P6 to con rm - press P1 several times to exit the menu
Press key P6
press P2 until ADJUSTMENTS SET is displayed.
Press P6 to con rm
press P2 until BOILER SETTING is displayed.
Press P4-P5 to con gure the setting
Press P6 to con rm - press P1 several times to exit the menu
Press key P6
press P2 until STATUS is displayed.
Press P6 to con rm
press P2 until BOILER STATUS is displayed.
Press P4-P5 to browse through the readout
Press P1 several times to exit the menu
BOILER STATUS
SB0
Set boiler max
SB1
Set Boiler min
SB2
Boiler temperature
SB3
Boiler output status
47