HEATING STATUS
The menu allows to check the status of the outputs relative to heating.
STATUS
HEATING STATUS
PUFFER STATUS
The menu allows to check the status of the pu er. Allows to check the setting of the maximum and minimum temperature, the superior and inferior temperature of the storage tank in real time
and the status of the relative output.
STATUS
PUFFER STATUS

USER MENU

Along with the standard settings, this menu allows satisfying the DHW storage tank requests within certain time bands.
BOILER CHRONO
The BOILER CHRONO menu allows to satisfy the requests of the domestic hot water storage tank only within certain time periods pre-established by the user and the same for every
day of the week. For example, if the user requires a hot storage tank in the morning, where there may be more request, a time period can be set from 6:30 to 8:00, within which the
storage tank will be satis ed at the temperature set in the set boiler menu. Outside of this time period, the requests of the domestic hot water storage tank will not be considered.
BOILER CHRONO
Š Press key P6
Š press P2 until STATUS is displayed.
Š Press P6 to con rm
Š press P2 until HEATING STATUS is displayed.
Š Press P4-P5 to browse through the readout
Š Press P1 several times to exit the menu
Š Press key P6
Š press P2 until STATUS is displayed.
Š Press P6 to con rm
Š press P2 until PUFFER STATUS is displayed.
Š Press P4-P5 to browse through the readout
Š Press P1 several times to exit the menu
Š Press key P6
Š press P2 until USER MENU is displayed.
Š Press P6 to con rm
Š press P2 until BOILER CHRONO is displayed.
Š Press P6 to con rm
Š Press P4-P5 to browse through the readout
Š Press P1 several times to exit the menu
HEATING STATUS
SR0
Input I1 status
SR1
Output OUT1 status
SR2
Output I2 status
SR3
Output OUT2 status
SR4
Output I3 status
SR5
Output OUT3 status
SR6
Input I4 status:
SR7
Output OUT4 status
PUFFER STATUS
SP0
Set pu er max
SP1
Set pu er min
SP2
Highest pu er temperature
SP3
Lowest pu er temperature
SP4
Pu er output status
TIMER PERIOD
VALUE
MEANING
START PG1
06:00
start of the rst time period
STOP PG1
08:00
end of the rst time period
START PG2
OFF
start of the second time period
STOP PG2
OFF
end of the second time period
START PG3
OFF
start of the third time period
STOP PG3
OFF
end of the third time period
START PG4
OFF
start of the fourth time period
STOP PG4
OFF
end of the fourth time period