ACCESS TO HP MENUS

TEMPERATURE ADJUSTMENT

As well as the normal standard settings, thanks to the use of the additional board, the TEMPERATURE menu o ers the following further possibilities:
Boiler maximum and minimum setting (dhw storage tank)
Š
Pu er maximum and minimum setting
Š
BOILER TEMPERATURE SETTING
Note: if an instant heat exchanger is present for the production of domestic hot water, it will not be possible to set any temperature set
PUFFER TEMPERATURE SETTING
Note: the screen is not displayed if the pu er is deactivated

ADJUSTMENTS MENU

As well as the standard "enable chrono" and "pellet adjustment" settings, the use of the additional board allows for the following other options:
SEASON
In SUMMER mode, the room thermostats relative to the heating system are satis ed. As well as the areas, the request on behalf of any pu er is inhibited: the boiler will only
work to satisfy the request for domestic hot water. In WINTER mode, all requests are considered.
ENABLE BOILER CHRONO
The menu allows to enable or disable the boiler chrono function used to satisfy the domestic hot water storage tank requests in some time periods pre-established
by the user.
For programming of the time periods and the explanation of the menu, see SET BOILER CHRONO sub-chapter.

BOILER SETTING

BIOMASSA
BIOMASSA
BIOMASSA AUX
BIOMASSA AUX
This menu allows setting the boiler in BIOMASS mode; the boiler operates without managing other auxiliary boilers, where present.
AUX
AUX
BIOMASS / AUX, where the boiler can manage also an auxiliary boiler or AUX, where the pellet boiler is excluded from operation, leaving only the auxiliary boiler.