Check The Operation Of The Loaded Camera; Perform The Final Checks; Visual Inspection - Olympus PT-E02 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 161

Check the operation of the loaded camera.

After sealing the Case, check that the camera functions normally.
• Operate the power switch lever on the Case and confirm that the camera is turned ON/OFF.
• Turn the mode dial knob on the Case and confirm that the camera mode switches properly.
• Operate the shutter lever on the Case and confirm that the camera shutter is released.
• Operate the zoom dial on the Case and confirm that the camera's lens is controlled.
• Operate other control buttons on the Case and confirm that the camera functions properly as
intended.
CAUTION
: • If the camera does not function properly, remove the camera and reload it,
starting from "Check the digital camera," on page E-16 of this manual.
• After loading the camera in the Case, confirm that the Case's mode dial can
be rotated. If not, the Case's mode dial may not be positioned properly on
the camera's mode dial. Set the mode dials properly.

Perform the final checks.

Visual Inspection

After closing the case tightly, check the seal between the front and rear lids and the
connection between the port and case to make sure the O-rings are not twisted, that they
sit properly in the grooves, and that no foreign matter has been caught between the two
parts.
CAUTION
: • Hairs, fibers, and other narrow items are not very apparent, but they may
cause entry of water, so that special attention is required.
Open
Close
E-24