Installation Requirements; Location Requirements - GE GXSH4OV Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Requirements.
LOCATION REQUIREMENTS
Consider all of the following when selecting an
installation location for the water softener.
Do not locate the water softener where freezing
temperatures occur. Do not attempt to treat
water over 120°F. Freezing temperatures
or
hot water damage voids the warranty.
To condition all water in the home, install
the water softener close to the water supply
inlet, and upstream of all other plumbing
connections, except outside water pipes.
Outside faucets should remain on hard water to
avoid wasting conditioned water and salt.
A nearby drain is needed to carry away
regeneration discharge (drain) water. Use a
floor drain,laundry tub, sump, standpipe, or
other options(check your local codes). See
"Air Gap Requirements" and "Valve Drain
Requirements"sections.
The water softener uses a direct plug-in
external power supply (included). Be sure to
use the included power supply and plug it into
a nominal 120V, 60 cycle household outlet that
is in a dry location only, grounded and properly
protected by an over current device such as a
circuit breaker or fuse.
Always install the water softener between
the water inlet and water heater. Any other
installed water conditioning equipment should
be installed between the water inlet and water
softener (See Figure below).
DO NOT RUN HOT WATER THROUGH
THE
SOFTENER. Temperature
of water passing
through
the softener
must be less than
120 ° F.
Avoid installing
in direct sunlight.
Excessive
sun
heat may cause distortion
or other damage
to
non-metallic
parts.
Outside
installation
is not recommended
and
voids the warranty.
Do not install the softener
where it would
block
access to the water
heater or access to the
main water
shutoff.
DIMENSIONS
_
22-7/16"
3-3/4"
_{t
:
IIMI
IL °
I
14-7/16"
TOP
VIEW
IN - OUT
47-5/8"
41-1/2"
SIDE VIEW
FRONT VIEW
PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
UntreatedWater to --.--
I
. I_'_
City Water Supply
.,_Outside Faucets_l_shut
off
i
ColdWater to House
_
"--I_
valve
/_
Optional
I,
Tank
OR
I
I
_=I Sediment If
_
I
Wo_er
;aJer
Filter
U
I
!ell
2ter
Supply
Heater
Softener
Pump
Well
_
8

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Gxsh45v

Tabla de contenido